NMR永磁体精密温度控制器的设计与实现

  • 杨畅 ,
  • 陈俊飞 ,
  • 陈黎 ,
  • 张志 ,
  • 冯继文 ,
  • 陈方 ,
  • 刘朝阳
展开
  • 1. 波谱与原子分子物理国家重点实验室, 武汉磁共振中心, 中国科学院生物磁共振分析重点实验室(中国科学院 武汉物理与数学研究所), 湖北 武汉 430071;
    2. 中国科学院大学, 北京 100049

收稿日期: 2018-04-16

  网络出版日期: 2018-08-28

基金资助

国家重大科研装备研制项目(ZDYZ2010-2);国家重大科研仪器研制项目(81627901);国家自然科学基金资助项目(11575287);国家自然科学基金青年科学基金资助项目(11705274);中国科学院科研装备研制项目(YZ201677,YZ201551).

Design and Implementation of NMR Permanent Magnet Precision Temperature Controller

  • YANG Chang ,
  • CHEN Jun-fei ,
  • CHEN Li ,
  • ZHANG Zhi ,
  • FENG Ji-wen ,
  • CHEN Fang ,
  • LIU Chao-yang
Expand
  • 1. State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, National Center for Magnetic Resonance in Wuhan, CAS Key Laboratory of Bio-magnetic Resonance Analysis(Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences), Wuhan 430071, China;
    2. University of Chinese Academy of Sciences, Beijing 100049, China

Received date: 2018-04-16

  Online published: 2018-08-28

摘要

低场核磁共振(low-field NMR)谱仪常采用钕铁硼(NdFeB)永磁体提供静磁场.NdFeB对温度非常敏感,磁体温度变化会引起磁场漂移,影响NMR实验的可靠性.为提高低场磁共振谱仪的稳定性,本文提出了一种基于双回路控制算法的磁共振永磁体精密温度控制方案,并在0.06 T磁共振谱仪上进行验证.结果表明:24 h内控温精度达到±0.005℃;相比无温控时,质子共振频率0.5 h内漂移量由255 Hz减小至15 Hz,24 h内漂移量由4 950 Hz减小至145 Hz,有效提高了低场磁共振谱仪永磁体的稳定性.

本文引用格式

杨畅 , 陈俊飞 , 陈黎 , 张志 , 冯继文 , 陈方 , 刘朝阳 . NMR永磁体精密温度控制器的设计与实现[J]. 波谱学杂志, 2018 , 35(3) : 294 -302 . DOI: 10.11938/cjmr20182632

Abstract

Neodymium-iron-boron (NdFeB) permanent magnets always used to generate a static magnetic field in low field NMR spectrometers has poor temperature stability. Temperature fluctuations will affect the reliability of NMR experiments. In order to improve the stability of low-field magnetic resonance spectrometer, a precise temperature control scheme of permanent magnet based on dual-loop control algorithm was proposed and verified on 0.06 T NMR spectrometer. The results show that the 24 h temperature control accuracy is better than ±0.005℃. And the drift in 1H resonance frequency decreases from 255 Hz to 15 Hz within 0.5 h, and from 4 950 Hz to 145 Hz within 24 h, compared to that without temperature control. That improves the stability of low-field NMR spectrometer with permanent magnet effectively.

参考文献

[1] ZHANG Y, BLÜMICH B. Gint2D-T2 correlation NMR of porous media[J]. J Magn Reson, 2015, 252:176-186.
[2] ZHANG Y, XIAO L Z, LIAO G Z, et al. Direct correlation of diffusion and pore size distributions with low field NMR[J]. J Magn Reson, 2016, 269:196-202.
[3] LIU H B, NOGUEIRA D E M, OBRUCHKOV S, et al. Determining pore length scales and pore surface relaxivity of rock cores by internal magnetic fields modulation at 2MHz NMR[J]. J Magn Reson, 2014, 246:110-118.
[4] MITCHELL J. Rapid measurements of heterogeneity in sandstones using low-field nuclear magnetic resonance[J]. J Magn Reson, 2014, 240:52-60.
[5] LEWIS R T, DJURHUUS K, SELAND J G. Characterising oil and water in porous media using decay due to diffusion in the internal field[J]. J Magn Reson, 2015, 259:1-9.
[6] 陈海玲. 钕铁硼永磁材料热稳定性快速检测方法的研究[D]. 沈阳:沈阳工业大学, 2005.
[7] 胡志华. 烧结Nd-Fe-B磁体的磁性能、温度稳定性以及冲击韧性研究[D]. 沈阳:东北大学, 2009.
[8] KIM S H, DOOSE C. Temperature compensation of NdFeB permanent magnets[C]//IEEE:Particle Accelerator Conference, 1998, 3:3227-3229.
[9] YAO B L, LIN Y, LIU X Q. Analysis of thermal performance of NdFeB permanent magnet[J]. Electric Machines & Control Application, 2008, 35(4):52-55. 姚丙雷, 林岩, 刘秀芹. 钕铁硼永磁材料热性能的分析[J]. 电机与控制应用, 2008, 35(4):52-55.
[10] 利格斯迈尔著, 张聚译. 嵌入式系统软件工程-基础知识, 方法和应用[M]. 北京:电子工业出版社, 2009.
[11] 乔治·埃利斯著, 汤晓君译. 控制系统设计指南[M]. 北京:机械工业出版社, 2016.
[12] HE Y G, FENG J W, ZHANG Z, et al. A peripheral component interconnect express-based scalable and highly integrated pulsed spectrometer for solution state dynamic nuclear polarization[J]. Rev Sci Instrum, 2015, 86(8):083101.
文章导航

/