研究论文

散弹噪声极限稳定度优于1×10-13τ-1/2的铷频标物理系统

  • 聂帅 ,
  • 王鹏飞 ,
  • 赵峰 ,
  • 王芳 ,
  • 明刚 ,
  • 邱紫敬 ,
  • 康松柏 ,
  • 梅刚华
展开
  • 1. 中国科学院精密测量科学与技术创新研究院, 湖北 武汉 430071
    2. 中国科学院原子频标重点实验室, 湖北 武汉 430071
    3. 中国科学院大学, 北京 100049

收稿日期: 2021-03-18

  网络出版日期: 2021-04-09

基金资助

中国科学院重点部署项目(ZDRW-KT-2021-2);国家自然科学基金青年科学基金资助项目(11903069)

A Physics Package with Shot-noise Limited Frequency Stability Better Than 1×10-13τ-1/2 for Rubidium Atomic Frequency Standards

  • Shuai NIE ,
  • Peng-fei WANG ,
  • Feng ZHAO ,
  • Fang WANG ,
  • Gang MING ,
  • Zi-jing QIU ,
  • Song-bai KANG ,
  • Gang-hua MEI
Expand
  • 1. Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China
    2. Key Laboratory of Atomic Frequency Standards, Chinese Academy of Sciences, Wuhan 430071, China
    3. University of Chinese Academy of Sciences, Beijing 100049, China

Received date: 2021-03-18

  Online published: 2021-04-09

摘要

近年来,铷原子频标研究取得长足进展,频率稳定度达到10-13τ-1/2量级.为进一步改善铷频标稳定度性能,本文设计了一种高信噪比物理系统.物理系统中的腔泡组件采用微波场磁力线与量子化轴方向高度平行的开槽管式微波腔,滤光泡和吸收泡独立控温.抽运光源采用了光学滤光和同位素滤光双重滤光方案.本文实测了背景光电流I0和鉴频斜率Kd,结果分别为95 μA和7.7 nA/Hz,在此基础上计算物理系统的散弹噪声极限稳定度为7.5×10-14τ-1/2.研究结果表明,只要锁频环路的电子学噪声得到有效控制,铷频标的频率稳定度突破1×10-13τ-1/2,进入10-14τ-1/2量级是完全可能的.

本文引用格式

聂帅 , 王鹏飞 , 赵峰 , 王芳 , 明刚 , 邱紫敬 , 康松柏 , 梅刚华 . 散弹噪声极限稳定度优于1×10-13τ-1/2的铷频标物理系统[J]. 波谱学杂志, 2022 , 39(1) : 108 -114 . DOI: 10.11938/cjmr20212897

Abstract

The performance of the rubidium (Rb) atomic frequency standard has achieved significant improvement in recent years. Its frequency stability has already reached the order of 10-13τ-1/2. To further improve Rb frequency standard's stability performance, we developed a high signal-to-noise ratio (SNR) physics package whose cavity-cell assembly consists of a slotted-tube microwave cavity, separated filter and absorption cells. The microwave cavity has a homogenous field distribution along the quantization axis, and the filter and absorption cells are temperature-controlled independently. We also used an optical and isotopic filtering scheme to suppress shot noise from the pumping light. The physics package's final background photocurrent I0 and the frequency discrimination slope Kdwere measured to be 95 μA and 7.7 nA/Hz, respectively, and the calculated limit stability of the shot noise of the physical package was 7.5×10-14τ-1/2. The result shows that Rb frequency standard can reach an unprecedented stability level below 1×10-13τ-1/2 as long as the electronic system's noise could be well controlled.

参考文献

1 RILEY J W. Rubidium atomic frequency standards for GPS block ⅡR[C]//Proceedings of 22nd Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting. Vienna, Virginia, 1990: 221-230.
2 DUPUIS R T, LYNCH T J, VACCARO J R, et al. Rubidium frequency standard for the GPS ⅡF program and modifications for the RAFSMOD program[C]//Proceedings of the 23rd International Technical Meeting of the Satellite Division of the Institute of Navigation (ION GNSS 2010). 2010: 781-788
3 RILEY J W. A history of the rubidium frequency standard[OL]. http://ieee-uffc.org/about-us/history/a-history-of-the-rubidium-frequency-standard.pdf. 2019.
4 iSpace+ Space Qualified RAFS Spec[R]. https://www.orolia.com/sites/default/files/document-files/Spectratime-RAFS-Spec-01-19-21.pdf. 2021.
5 MEI G H, ZHONG D, AN S F, et al. Main features of space rubidium atomic frequency standard for BeiDou satellites[C]//2016 European Frequency and Time Forum (EFTF). IEEE, 2016: 1-4.
6 MEI G H , ZHAO F , Qi F , et al. Characteristics of the space-borne rubidium atomic clocks for the BeiDou Ⅲ navigation satellite system[J]. Scientia Sinica: Physica, Mechanica & Astronomica, 2021, 51 (1): 118- 124.
6 梅刚华, 赵峰, 祁峰, 等. 用于北斗三号卫星导航系统的星载铷原子钟特性[J]. 中国科学: 物理学力学天文学, 2021, 51 (1): 118- 124.
7 HAO Q , LI W B , HE S G , et al. A physics package for rubidium atomic frequency standard with a short-term stability of 2.4×10- 13τ-1/2[J]. Rev Sci Instrum, 2016, 87 (12): 123111.
8 NIE S, WANG P F, QIU Z J, et al. A lamp-pumped rubidium atomic frequency standard with a short-term stability at the level of 2×10-13τ-1/2[C]//China Satellite Navigation Conference (CSNC) 2019 proceedings. Springer, Singapore, 2019: 556-563.
9 BANDI T , AFFOLDERBACH C , STEFANUCCI C . et al, Compact high-performance continuous-wave double-resonance rubidium standard with 1.4×10-13τ-1/2 stability[J]. IEEE transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014, 61 (11): 1769- 1778.
10 VANIER J . On the signal-to-noise ratio and short-term stability of passive rubidium frequency standards[J]. IEEE T Instrum Meas, 1981, 30 (4): 277- 282.
11 XU F , HAO Q , WANG P F , et al. A high signal to noise ratio physics package with a slotted-tube cavity for rubidium atomic clock[J]. Acta Metrologica Sinica, 2016, 37 (4): 437- 440.
11 许风, 郝强, 王鹏飞, 等. 基于开槽管腔的高信噪比铷原子钟物理系统[J]. 计量学报, 2016, 37 (4): 437- 440.
12 MICALIZIO S , GODONE A , LEVI F , et al. Pulsed optically pumped 87Rb vapor cell frequency standard: A multilevel approach[J]. Phys Rev A, 2009, 79 (1): 013403.
13 MEI G H, ZHONG D, AN S F, et al. Miniaturized microwave cavity for atomic frequency standard: U.S. Patent, 6, 225, 870[P], 2001-05-01.
14 STEFANUCCI C , BANDI T , MERLI F , et al. Compact microwave cavity for high performance rubidium frequency standards[J]. Rev Sci Instrum, 2012, 83, 104706.
文章导航

/