研究论文

7 T 下脂肪对基于 NOE 的磁共振对比成像的影响

  • 张苗1 ,
  • 卢建华2 ,
  • 蔡聪波3 ,
  • 蔡淑惠1*
展开
  • 1. 厦门大学 电子科学系,福建省等离子体与磁共振研究重点实验室,福建 厦门 361005;
    2. Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA 70803, USA;
    3. 厦门大学 通信工程系,福建 厦门 361005
张苗(1989-), 女, 河北石家庄人, 硕士研究生, 无线电物理专业. *通讯联系人: 蔡淑惠, 电话: 0592-2183301, E-mail: shcai@xmu.edu.cn.

收稿日期: 2015-02-04

  修回日期: 2015-10-25

  网络出版日期: 2015-12-05

基金资助

国家自然科学基金资助项目(U1232212, 81171331),高等学校博士学科点专项科研基金资助项目(20130121110014)

Effects of Lipids Signals on Nuclear Overhauser Enhancement Contrast Imaging at 7 T

  • ZHANG Miao1 ,
  • LU Jian-hua2 ,
  • CAI Cong-bo3 ,
  • CAI Shu-hui1*
Expand
  • 1. Department of Electronic Science, Xiamen University, Fujian Key Laboratory of Plasma and Magnetic Resonance, Xiamen 361005, China;
    2. Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA 70803, USA;
    3. Department of Communication Engineering, Xiamen University, Xiamen 361005, China

*Corresponding author: CAI Shu-hui, Tel: +86-592-2183301, E-mail: shcai@xmu.edu.cn.

Received date: 2015-02-04

  Revised date: 2015-10-25

  Online published: 2015-12-05

Supported by

国家自然科学基金资助项目(U1232212, 81171331),高等学校博士学科点专项科研基金资助项目(20130121110014)

摘要

Overhauser 增强(NOE)效应在高场下的化学交换饱和转移中会造成 Z 谱高场位置的负背景信号,有望成为一种新的磁共振成像(MRI)对比机制.然而,研究指出, NOE信号的发生区域与主要的脂肪信号的频率位置有重叠,因此 MRI 中观察到的 NOE 信号有可能混合了脂肪信号.该文通过鸡蛋的模型实验,初步分析了脂肪含量较高的组织内脂肪信号对 NOE 效应的影响,并通过健康大鼠鼠脑及颅内肿瘤大鼠鼠脑实验,分析了脂肪对脑NOE 对比成像及基于 NOE 对比成像的疾病诊断的影响.结果表明,脂肪含量较高的组织内脂肪信号会引起伪 NOE 效应,并影响 NOE 对比图像的准确性.

本文引用格式

张苗1 , 卢建华2 , 蔡聪波3 , 蔡淑惠1* . 7 T 下脂肪对基于 NOE 的磁共振对比成像的影响
[J]. 波谱学杂志, 2015
, 32(4) : 606 -617 . DOI: 10.11938/cjmr20150406

Abstract

When performing chemical exchange saturation transfer (CEST) magnetic resonance imaging (MRI) on biological samples at high fields, nuclear Overhauser enhancement (NOE) effects may produce negative signals on the Z-spectra. The NOE-related signal intensity changes have the potential to become a new contrast mechanism. However, the presence of lipids signals within the same chemical shift range may affect the observation of true NOE effect-related signal changes. In this work, we first analyzed the influence of lipid signals on the NOE effects in tissues abundant in lipid via experiments on eggs. Similar experiments were then carried out on healthy rats and rats with brain tumors. The results showed that the presence of large lipid signals could cause pseudo NOE effects and degrade the accuracy of NOE contrast imaging.

参考文献

 


[1]          Ward K, Aletras A, Balaban R, et al. A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST)[J]. J Magn Reson, 2000, 143(1): 79-87.

[2]          Zhou J, Van Zijl P C. Chemical exchange saturation transfer imaging and spectroscopy[J]. Prog Nucl Magn Reson Spectrosc, 2006, 48(2-3): 109-136.

[3]          Sherry A D, Woods M. Chemical exchange saturation transfer contrast agents for magnetic resonance imaging[J]. Annu Rev Biomed Eng, 2008, 10: 391-411.

[4]          Vinogradov E, Sherry A D, Lenkinski R E, et al. CEST: From basic principles to applications, challenges and opportunities[J]. J Magn Reson, 2013, 229: 155-172.

[5]          Kogan F, Hariharan H, Reddy R, et al. Chemical exchange saturation transfer (CEST) imaging: Description of technique and potential clinical applications[J]. Curr Radiol Rep, 2013, 1(2): 102-114.

[6]          Solomon I. Relaxation processes in a system of two spins[J]. Phys Rev, 1955, 99(2): 559-565.

[7]          Jin T, Wang P, Zong X, et al. MR imaging of the amide-proton transfer effect and the pH-insensitive nuclear Overhauser effect at 9.4 T[J]. Magn Reson Med, 2013, 69(3): 760-770.

[8]          Ling W, Regatte R R, Navon G, et al. Assessment of glycosaminoglycan concentration in vivo by chemical exchange-dependent saturation transfer (gagCEST)[J]. Proc Natl Acad Sci USA, 2008, 105(7): 2 266-2 270.

[9]          Jones C K, Huang A, Xu J, et al. Nuclear Overhauser enhancement (NOE) imaging in the human brain at 7 T[J]. NeuroImage, 2013, 77: 114-124.

[10]       Cai K, Haris M, Singh A, et al. Magnetic resonance imaging of glutamate [J]. Nat Med, 2012, 18(2): 302-306.

[11]       Hua J, Jones C K, Blakeley J, et al. Quantitative description of the asymmetry in magnetization transfer effects around the water resonance in the human brain[J]. Magn Reson Med, 2007, 58(4): 786-793.

[12]       Van Zijl P C, Zhou J, Mori N, et al. Mechanism of magnetization transfer during on-resonance water saturation. A new approach to detect mobile proteins, peptides, and lipids[J]. Magn Reson Med, 2003, 49(3): 440-449.

[13]       Zhou J, Blakeley J O, Hua J, et al. Practical data acquisition method for human brain tumor amide proton transfer (APT) imaging[J]. Magn Reson Med, 2008, 60(4): 842-849.

[14]       Zhou J, Hong X, Zhao X, et al. APT-weighted and NOE-weighted image contrasts in glioma with different RF saturation powers based on magnetization transfer ratio asymmetry analyses[J]. Magn Reson Med, 2013, 70(2): 320-327.

[15]       Mougin O E, Coxon R C, Pitiot A, et al. Magnetization transfer phenomenon in the human brain at 7 T[J]. NeuroImage, 2010, 49(1): 272-281.

[16]       Liu D, Zhou J, Xue R, Zuo Z, et al. Quantitative characterization of nuclear Overhauser enhancement and amide proton transfer effects in the human brain at 7 T[J]. Magn Reson Med, 2013, 70(4): 1 070-1 081.

[17]       Zaiss M, Kunz P, Goerke S, et al. MR imaging of protein folding in vitro employing Nuclear-Overhauser-mediated saturation transfer[J]. NMR Biomed, 2013, 26(12): 1 815-1 822.

[18]       Behar K L, Rothman D L, Spencer D D, et al. Analysis of macromolecule resonances in 1H NMR spectra of human brain[J]. Magn Reson Med, 1994, 32(3): 294-302.

[19]       Lu J, Zhou J, Cai C, et al. Observation of true and pseudo NOE signals using CEST-MRI and CEST-MRS sequences with and without lipid suppression[J]. Magn Reson Med, 2014, doi:10.1002/mrm.25277.

[20]       Jones C K, Polders D, Hua J, et al. In vivo three-dimensional whole-brain pulsed steady state chemical exchange saturation transfer at 7 T[J]. Magn Reson Med, 2012, 67(6): 1 579-1 589.

[21]       Dewey B. Simulation and Optimization of Pulsed Chemical Exchange Saturation Transfer for Clinical Application at 3 T [D]. Nashville, Tennessee, USA: Vanderbilt University, 2013.
文章导航

/