A Study on Self-Absorption of Spectral Lines of Rubidium Spectral Lamp

  • HAO Qiang ,
  • XU Feng ,
  • WANG Fang ,
  • ZHAO Feng ,
  • ZHONG Da ,
  • MEI Gang-hua ,
  • HE Sheng-guo
Expand
  • 1. Key Laboratory of Atom Frequency Standard of the Chinese Academy of Sciences, (Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences), Wuhan 430071, China;
    2. University of Chinese Academy of Sciences, Beijing 100049, China

Received date: 2015-04-27

  Revised date: 2016-04-16

  Online published: 2016-06-05

Abstract

Spectral line profile distortion, resulted from self-absorption of rubidium atoms in the rubidium spectral lamp bulb, is detrimental to the frequency stability of rubidium frequency standard. In this study, the hyperfine spectral profiles of rubidium lamps were studied with an F-P interferometer, and the influence of the type and pressure of buffer gas, lamp operating temperature and radio frequency-excitation power on self-absorption was examined. The results showed that the lamps filled with Ar gas or Kr gas showed serious self-absorption, while Xe-filled lamps had less self-absorption. Self-absorption could also be reduced by either sufficiently decreasing the operating temperature or increasing the pressure of buffer gas and rf-excitation power of the lamp.

Cite this article

HAO Qiang , XU Feng , WANG Fang , ZHAO Feng , ZHONG Da , MEI Gang-hua , HE Sheng-guo . A Study on Self-Absorption of Spectral Lines of Rubidium Spectral Lamp[J]. Chinese Journal of Magnetic Resonance, 2016 , 33(2) : 288 -294 . DOI: 10.11938/cjmr20160211

References

[1] Wang Yi-qiu(王义遒), Wang Qing-ji(王庆吉), Fu Ji-shi(傅济时), et al. Quantum Frequency Standard Theory(量子频标原理)[M]. Beijing(北京):Science Press(科学出版社), 1986.

[2] Gibbs H M, Hull P J. Spin-exchange cross sections for Rb87-Rb-87 and Rb87-Cs133 collisions[J]. Phys Rev, 1967, 153(1):132-154.

[3] Cowan R D, Dieke G H. Self-absorption of spectral lines[J]. Rev Mod Phys, 1948, 20(2):418-455.

[4] Hao Q, He S G, Xu F, et al. China Satellite Navigation Conference (CSNC) 2015 Proceedings[C]. Xi'an:Springer-verlag, Berlin, Heidelberg, 2015.

[5] Zhao Feng(赵峰), Zeng Yuan(曾媛), Wu Han-hua(吴汉华), et al. A Rubidium Discharge Lamp Used in Rubidium Frequency Standard(星载铷原子频标光谱灯研制)[C]. 贵阳:2003年全国时间频率学术会议, 2003.

[6] Dass T, Freed G, Petzinger J, et al. Proceedings of the 34th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting[C]. Reston U S A:US Naval Observatory, 2002.

Outlines

/