Acquisition parameters for chemical exchange saturation transfer (CEST) imaging were optimized on a GE Signa HDe 1.5 T magnetic resonance imaging (MRI) scanner with phantoms and clinical cases. The effects of matrix size, number of averages (NEX) and flip angles on the quality of CEST images were assessed. It was shown that the signal-to-noise ratio (SNR) of the CEST images acquired on the 1.5 T scanner was relatively low, and the stability and uniformity of the B0 field affected the outcome significantly. Reducing matrix size and increasing NEX improved the SNR of the CEST images. Optimal flip angle for magnetization transfer was found to be 105°. With a NEX of 2, usable Z spectra could be obtained. The Z spectra indicated that, with the saturation pulse frequency centered at -294~-194 Hz, signal differences could be observed for 30% Glu, I320, H2O, and Cr. Maximal signal differences were observed when the saturation pulse applied at -244~-214 Hz. Amide proton transfer (APT) imaging on patients showed that 25 cases of brain tumor had high CEST signals, 12 cases of cerebral infarction had low CEST signals. It was therefore possible to differentiate brain tumor from infarction with CEST imaging. There were also 12 cases which failed due to long acquisition time, patient movements, and temperature changes in the scanner room.
GUO Gang
,
CAI Cong-bo
,
YANG Yong-gui
,
CHEN Zhong
. Factors Affecting Chemical Exchange Saturation Transfer Imaging on 1.5 T Clinical MRI Scanners[J]. Chinese Journal of Magnetic Resonance, 2017
, 34(3)
: 275
-282
.
DOI: 10.11938/cjmr20162553
[1] WARD K M, ALETRAS A H, BALABAN R S. A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST)[J]. J Magn Reson, 2000, 143(1):79-87.
[2] HUA J, JONES C K, BLAKELEY J, et al. Quantitative description of the asymmetry in magnetization transfer effects around the water resonance in the human brain[J]. Magn Reson Med, 2007, 58(4):786-793.
[3] YANG Y G, SHEN Z W, WU R H, et al. Research of chemical exchange saturation transfer in brain[J]. Chin J Magn Reson Imaging, 2016, 7(4):81-84. 杨永贵, 沈智威, 吴仁华, 等. 脑部化学交换饱和转移成像研究[J]. 磁共振成像, 2016, 7(4):81-84.
[4] VAN ZIJL P C M, YADAV N N. Chemical exchange saturation transfer (CEST):What is in a name and what isn't?[J]. Magn Reson Med, 2011, 65(4):927-948.
[5] WANG S, JARSO S, VAN ZIJL P C, et al. Role of amide proton transfer (APT)-MRI of endogenous proteins and peptides in brain tumor imaging[M]. New York:Springer, 2014:171-181.
[6] MORI S, ELEFF S M, PILATUS U, et al. Proton NMR spectroscopy of solvent-saturable resonances:A new approach to study pH effects in Situ[J]. Magn Reson Med, 1998, 40(1):36-42.
[7] SUN P Z, WANG E, CHEUNG J S, et al. Simulation and optimization of pulsed radio frequency (RF) irradiation scheme for chemical exchange saturation transfer(CEST) MRI-demonstration of pH-weighted pulsed-amide proton CEST MRI in an animal model of acute cerebral ischemia[J]. Magn Reson Med, 2011, 66(4):1042-1048
[8] SUN P Z, ZHOU J, HUANG J, et al. Simplified quantitative description of amide proton transfer (APT) imaging during acute ischemia[J]. Magn Reson Med, 2007, 57(2):405-410.
[9] SUN P Z, ZHOU J, SUN W, et al. Detection of the ischemic penumbra using pH-weighted MRI[J]. J Cereb Blood Flow Metab, 2007, 27(6):1129-1136.