Cardiac magnetic resonance imaging (CMRI) is a non-invasive technique that features multi-contrast and allows imaging at arbitrary orientations. However, the clinical applications of cardiac MRI are limited, mainly due to its long scan time. To speed up cardiac CINE imaging, a multi-fold accelerated cardiac CINE imaging method based on simultaneous multi-slice imaging and reconstruction technique was proposed. By combining the controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique and a partial parallel acquisition (PPA) scheme, a four-fold acceleration (i.e., 2-fold along the phase encoding direction and 2-fold along the slice encoding direction) was achieved. The proposed technique was tested and verified on phantoms and human subjects using an improved image reconstruction method SENSE/GRAPPA. Results demonstrated that the proposed method is effective in reducing cardiac CINE scan time, while preserving image quality and accuracy of cardiac function assessment.
ZHAO Le-le
,
CHEN Li-yong
,
HUANG Xiao-qian
,
XU Jian
,
CHEN Qun
. Accelerated Cardiac CINE Imaging with CAIPIRINHA and Partial Parallel Acquisition[J]. Chinese Journal of Magnetic Resonance, 2017
, 34(3)
: 283
-293
.
DOI: 10.11938/cjmr20172555
[1] PENNELL D J, SECHTEM U P, HIGGINS C B, et al. Clinical indications for cardiovascular magnetic resonance (CMR):Consensus Panel report[J]. Eur Heart J, 2004, 25(21):1940-1965.
[2] PETITJEAN C, DACHER J N. A review of segmentation methods in short axis cardiac MR images[J]. Med Image Anal, 2011, 15(2):169-184.
[3] HEIDEMANN R M, ÖZSARLAK Ö, PARIZEL P M, et al. A brief review of parallel magnetic resonance imaging[J]. Eur Radiol, 2003, 13(10):2323-2337.
[4] BREUER F A, BLAIMER M, HEIDEMANN R M, et al. Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging[J]. Magn Reson Med, 2005, 53(3):684-691.
[5] BARTH M, BREUER F, KOOPMANS P J, et al. Simultaneous multislice (SMS) imaging techniques[J]. Magn Reson Med, 2016, 75(1):63-81.
[6] OPPELT B A, GRAUMANN R, BARFUB H, et al. FISP:A new fast MRI sequence[J]. Electromedica, 1986, 54:15-18.
[7] WEBER O M, SPEIER P, SCHEFFLER K, et al. Assessment of magnetization transfer effects in myocardial tissue using balanced steady-state free precession (bSSFP) cine MRI[J]. Magn Reson Med, 2009, 62(3):699-705.
[8] STÄB D, RITTER C O, BREUER F A, et al. CAIPIRINHA accelerated SSFP imaging[J]. Magn Reson Med, 2011, 65(1):157-164.
[9] BLAIMER M, BREUER F A, SEIBERLICH N, et al. Accelerated volumetric MRI with a SENSE/GRAPPA combination[J]. J Magn Reson Imaging, 2006, 24(2):444-450.
[10] SOBOL W T, GAUNTT D M. On the stationary states in gradient echo imaging[J]. J Magn Reson Imaging, 1996, 6(2):384-398.
[11] PRUESSMANN K P, WEIGER M, SCHEIDEGGER B, et al. SENSE:sensitivity encoding for fast MRI[J]. Magn Reson Med, 1999, 42(5):952-962.
[12] GRISWOLD M A, JAKOB P M, HEIDEMANN R M, et al. Generalized autocalibrating partially parallel acqusitions(GRAPPA)[J]. Magn Reson Med, 2002, 47(6):1202-1210.
[13] SETSOMPOP K, GAGOSKI B A, POLIMENI J R, et al. Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty[J]. Magn Reson Med, 2012, 67(5):1210-1224.
[14] KELLMAN P, MCVEIGH E R. Image reconstruction in SNR units:A general method for SNR measurement[J]. Magn Reson Med, 2005, 54(6):1439-1447.
[15] NEMA. National Manufacturers Electrical Association standards (MS1-2008):determination of signal-to-noise ratio in diagnostic magnetic resonance imaging[R]. 2008.
[16] DING Y, CHUNG Y C, SIMONETTI O P. A method to assess spatially variant noise in dynamic MR image series[J]. Magn Reson Med, 2010, 63(3):782-789.
[17] OTAZO R, KIM D, AXEL L, et al. Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI[J]. Magn Reson Med, 2010, 64(3):767-776.
[18] YUTZY S R, SEIBERLICH N, DUERK J L, et al. Improvements in multislice parallel imaging using radial CAIPIRINHA[J]. Magn Reson Med, 2011, 65(6):1630-1637.