The accuracy of gradient pulse waveform affects image quality significantly in magnetic resonance imaging (MRI). Recording and analyzing the waveform of gradient pulse helps to make rapid and accurate diagnosis of spectrometer gradient hardware and/or pulse sequence. Using the virtual instrument software LabVIEW to control the high speed data acquisition card DAQ-2005, a multi-channel acquisition scheme was designed to collect the gradient outputs from a custom-made spectrometer. The collected waveforms were post-processed (i.e., histogram statistical analysis, data filtering and difference calculation) to obtain feature points containing time and amplitude information. Experiments were carried out to validate the method, which is an auxiliary test method for the development of spectrometer and pulses sequence.
OU-YANG Shan-mei
,
LOU Yu-kun
,
XIAO Liang
. Analysis of Gradient Waveform in Magnetic Resonance Imaging[J]. Chinese Journal of Magnetic Resonance, 2017
, 34(4)
: 498
-507
.
DOI: 10.11938/cjmr20172563
[1]MAO W P,BAO Q J,YANG L,et al.A modularized pulse programmer for NMR spectroscopy[J].Meas Sci Technol,2011,22(2):025901. [2]STANG P P,CONOLLY S M,SANTOS J M,et al.A scalable MR console using USB[J].IEEE Trans Med Imaging,2012,31(2):370-379. [3]SEITARO H,KATSUMI K,TOMOYUKI H.Development of a pulse programmer for magnetic resonance imaging using a personal computer and a high-speed digital input-output board[J].Rev Sci Instrum,2012,83(5):053702. [4]LIU M,QIU W Q,SUN H J,et al.Progress in the portable NMR spectrometer[J].Chinese J Magn Reson,2014,31(4):504-514.刘敏,邱雯绮,孙惠军,等.便携式核磁共振谱仪的研究进展[J].波谱学杂志,2014,31(4):504-514. [5]YANG L,BAO Q J,MAO W P,et al.System performance evaluation of a self-developed NMR spectrometer[J].Chinese J Magn Reson,2012,29(1):78-85.杨亮,鲍庆嘉,毛文平,等.自主研制核磁共振波谱仪性能评估[J].波谱学杂志,2012,29(1):78-85. [6]LIU H D,WANG H W,ZHU T X,et al.A Frequency synthesizer for high-field NMR spectrometers[J].Chinese J Magn Reson,2014,31(1):91-99.刘海丹,王恢望,朱天雄,等.高场核磁共振波谱仪频率合成器设计[J].波谱学杂志,2014,31(1):91-99. [7]HE Y G,FENG J W,ZHANG Z,et al.Development of pulse dynamic nuclear polarization for enhancing NMR and MRI[J].Chinese J Magn Reson,2015,32(2):393-398.贺玉贵,冯继文,张志,等.脉冲动态核极化增强的NMR和MRI系统研究[J].波谱学杂志,2015,32(2):393-398. [8]LIU Y,ZHANG Y W,LIANG Z,et al.A Heterogeneous dual-core receiver system for magnetic resonance applications[J].Chinese J Magn Reson,2017,34(1):100-107.刘颖,张育文,梁浈,等.基于异构双核的磁共振接收机设计[J].波普学杂志,2017,34(1):100-107. [9]ZHUO J,GULLAPALLI R P.AAPM/RSNA physics tutorial for residents:MR artifacts,safety,and quality control[J].Radiographics,2006,26(1):275-297. [10]MORELLI J N,RUNG V M,AI F,et al.An image-based approach to understanding the physics of MR artifacts[J].Radiographics,2011,31(3):849-866. [11]LIU Y.Data process and signal analysis based on LabVIEW[C]//International conference on electronic measurement and instruments.IEEE,2009,doi:10.1109/ICEMI.2009.5274072. [12]XIONG Y,HAN J F,PAN S H,et al.Design of data acquisition system based on DSP and LabVIEW for car driving posture[J].Application of Electronic Technique,2011,37(1):80-83.熊玉,韩峻峰,潘盛辉,等.基于DSP与LabVIEW的汽车行驶姿态参数采集系统设计[J].电子技术应用,2011,37(1):80-83. [13]ZHOU H B,JIANG D G,KE Y B,et al.The heart sound signal detecting system based on STC microprocessor and LabVIEW[J].Application of Electronic Technique,2012,(1):31-33.周红标,蒋鼎国,柯永斌,等.基于STC单片机和LabVIEW的心音信号检测系统[J].电子技术应用,2012,(1):31-33. [14]YAO L,LIU D D.Design of the data acquisition and signal processing system based on LabVIEW[J].Electronic Sci&Tech,2012,25(5):79-81.姚丽,刘东东.基于LabVIEW的数据采集与信号处理系统设计[J].电子科学与技术,2012,25(5):79-81.