Methods to map radiofrequency (RF) field generated by an RF coil/pulse have been developed. By measuring the changes of RF field in biological tissues when an RF pulse passing through, the electrical properties of the tissue could be retrieved and used for early diagnosis of diseases such as cancer. So far, RF field mapping is mainly done for birdcage coils at high fields. Less research has been performed on phased array coils at low fields. This work studied how loading would affect the distribution of RF field in low-field MRI with permanent magnet (i.e., 17.8 MHz). Both finite element simulation and experimental results demonstrated that coil loading changed the uniformity of RF field significantly, and the distortion of RF field under the loaded condition could reflect the electrical characteristics of the loaded biological tissues.
CHEN Hai-yan
,
ZHAO Shi-long
,
LI Xiao-nan
,
LIU Guo-qiang
,
HU Li-li
,
LIU Tao
. B1 Mapping on Low-Field Permanent Magnet MRI Scanner[J]. Chinese Journal of Magnetic Resonance, 2018
, 35(4)
: 498
-504
.
DOI: 10.11938/cjmr20182661
[1] JOINES W T, ZHANG Y, LI C X, et al. The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz[J]. Med Phys, 1994, 21(4):547-550.
[2] LIU J E, ZHANG X T, VAN DE MOORTELE P F, et al. Determining electrical properties based on B1 fields measured in an MR scanner using a multi-channel transmit/receive coil:a general approach[J]. Phys Med Biol, 2013, 58(13):4395-4408.
[3] KATSCHER U, ABE H, IVANCEVIC M, et al. Systematic brain tumor conductivity study with optimized EPT sequence and reconstruction algorithm[C] 201321th Annual International Conference of the ISMRM. Salt Lake City:2013:33-40.
[4] HAEMMERICH D, STAELIN S T, TSAI J Z, et al. In vivol electrical conductivity of hepatic tumours[J]. Physiol Meas, 2003, 24(2):251-260.
[5] FRICKE H. The electric capacity of suspensions with special reference to blood[J]. J Gen Physiol, 1925, 9(2):137-152.
[6] HAACKE E M, PETROPOULOS L S, NILGES E W, et al. Xtraction of conductivity and permittivity using magnetic resonance imaging[J]. Phys Med Biol, 1991, 36(6):723-734.
[7] WEN H. Noninvasive quantitative mapping of conductivity and dielectric distributions using RF wave propagation effects in high field MRI[C]. Proc SPIE 5030, Medical Imaging 2003:Physics of Medical Imaging, 2003, doi:10.1117/12.480000.
[8] KATSCHER U, VOIGT T, FINDEKLEE C, et al. Determination of Electric conductivity and local SAR Via B1 mapping[J]. IEEE Trans Med Imaging, 2009, 28(9):1365-1374.
[9] ZHANG X T, SCHMITTER S, VAN DE MOORTELE P F, et al. From complex B1 mapping to local SAR estimation for human brain MR imaging using multi-channel transceiver coil at 7T[J]. IEEE Trans Med Imaging, 2013, 32(6):1058-1067.
[10] YANG B L. Future of ultra high field MRI in basic research and clinical applications[J]. Chinese J Magn Reson, 2015, 32(4):707-714. 杨保联. 超高场磁共振人体成像应用研究和医学前景[J]. 波谱学杂志, 2015, 32(4):707-714.
[11] 赵喜平. 磁共振成像[M]. 北京:科学出版社, 2004.
[12] ZHOU Z K, HU L Z, JIANG R R, et al. Rapid B1+ mapping based on actual flip-angle imaging[J]. Chinese J Magn Reson, 2016, 33(4):515-527. 周子堃, 胡凌志, 蒋瑞瑞, 等. 基于AFI的快速发射场B1+成像方法[J]. 波谱学杂志, 2016, 33(4):515-527.
[13] HE X W, YUAN R B, LI B K, et al. The design of an open MRI 4-channel receive-only phased array knee coil[J]. Appl Magn Reson, 2016, 47(5):499-510.
[14] XIN X G. Technological progresses of the magnetic resonance electrical property tomography of human tissues[J]. Chinese Journal of Biomedical Engineering, 2015, 34(1):83-90. 辛学刚. 人体组织电特性磁共振断层成像(MR EPT)技术进展[J]. 中国生物医学工程学报, 2015, 34(1):83-90.