Imaging Hippocampus of Mental Patients with BLADE Technique

  • SHAO Dan-dan ,
  • WANG Xue-xue ,
  • PAN Zi-lai ,
  • CHEN Ke-min ,
  • ZHANG Zhong-shuai ,
  • YUAN Li-li ,
  • XU Zi-yue ,
  • CHEN Lei ,
  • WANG Jin-hong
Expand
  • 1. Department of Radiology, Ruijin Hospital North, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China;
    2. Department of Medical Imaging, Mental Health Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200030, China;
    3. Siemens Healthcare, Shanghai 201318, China

Received date: 2018-12-11

  Online published: 2019-01-25

Abstract

BLADE is the commercial name of a spin-echo imaging technique that uses periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) k-space trajectory. In this study, the efficiency of using BLADE to improve hippocampal imaging in mental patients was assessed. The hippocampi of 47 mental patients were imaged on a 3.0 T scanner along the oblique coronal orientation using the T2WI TSE and T2WI FLAIR sequences with or without the use of BLADE. The same four sequences were also used to scan a standard American College of Radiology (ACR) phantom according to the ACR standards. The hippocampal images were scored by two radiologists using a 5-point scale, in terms of motion artifact, pulsation artifact, perceptive coarseness and image quality. The outcomes were compared between the sequences by two-sample Wilcoxon tests. The images of the phantom were evaluated semi-quantitatively for high contrast spatial resolution (HCSR) and low contrast object detection detectability (LCD) by counting the number of hole arrays and spokes that could be detected. The results showed that, compared to the conventional sequences, the sequences combined with BLADE technique showed significantly reduced motion and pulsation artifacts (p<0.001), improved image quality (p<0.05), but increased the perceptive coarseness (p<0.001). In the phantom experiments, the use of BLADE greatly improved the LCD, but had little effects on the HCSR. Based on these results, the BLADE technique is recommended for hippocampal imaging in mental patients with low compliance with the guidance.

Cite this article

SHAO Dan-dan , WANG Xue-xue , PAN Zi-lai , CHEN Ke-min , ZHANG Zhong-shuai , YUAN Li-li , XU Zi-yue , CHEN Lei , WANG Jin-hong . Imaging Hippocampus of Mental Patients with BLADE Technique[J]. Chinese Journal of Magnetic Resonance, 2019 , 36(3) : 261 -267 . DOI: 10.11938/cjmr20182700

References

[1] SCHER A I, XU Y, KORF E S, et al. Hippocampal shape analysis in Alzheimer's disease:a population-based study[J]. NeuroImage, 2007, 36(1):8-18.
[2] ADACHI M, HOSOYA T, HAKU T, et al. Evaluation of the substantia nigra in patients with parkinsonian syndrome accomplished using multishot diffusion-weighted MR imaging[J]. AJNR Am J Neuroradiol, 1999, 20(8):1500-1506.
[3] KIDA I, UEGUCHI T, MATSUOKA Y, et al. Comparison of diffusion-weighted imaging in the human brain using readout-segmented EPI and PROPELLER turbo spin echo with single-shot EPI at 7 T MRI[J]. Invest Radiol, 2016, 51(7):435-439.
[4] PANAYIOTIS M, ELEONORA G, ALEKSANDRA T, et al. Brain imaging:Comparison of T1W FLAIR BLADE with conventional T1W SE[J]. Magn Reson Imaging, 2017, 37(4):234-242.
[5] QIN W, YU C S, LI K C. Principle and applications of PROPELLER technique[J]. Journal of Medical Imaging, 2005, 15(10):912-915. 秦文, 于春水, 李坤成. 螺旋桨(PROPELLER)技术的原理及应用[J]. 医学影像学杂志, 2005, 15(10):912-915.
[6] TAE H K, MOON Y B, JI E P, et al. Comparison of DWI methods in the pediatric brain:PROPELLER turbo spin-echo imaging versus readout-segmented echo-planar imaging versus single-shot echo-planar imaging[J]. AJR Am J Roentgenol, 2018, 210(6):1352-1358.
[7] ELEFTHERIOS L, PANAYIOTIS M, SPIROS K, et al. Improvement of image quality using BLADE sequences in brain MR imaging[J]. Magn Reson Imaging, 2013, 31(2):189-200.
[8] NYBERG E, SANDHU G S, JESBERGER J, et al. Comparison of brain MR images at 1.5 T using BLADE and rectilinear techniques for patients who move during data acquisition[J]. AJNR Am J Neuroradiol, 2012, 33(1):77-82.
[9] MEIER S M, MARX C, SCHMEEL F C, et al. Revised PROPELLER for T2-weighted imaging of the prostate at 3 Tesla:impact on lesion detection and PI-RADS classification[J]. Eur Radiol, 2018, 28(1):24-30.
[10] MARCIN C, IZTOK C, JAMES T, et al. Role of PROPELLER-DWI of the prostate in reducing distortion and artifact from total hip replacement metalwork[J]. Eur J Radiol, 2018, 102(5):213-219.
[11] LAVDAS E, MAVROIDIS P, KOSTOPOULOS S, et al. Reduction of motion, truncation and flow artifacts using BLADE sequences in cervical spine MR imaging[J]. Magn Reson Imaging, 2015, 33(2):194-200.
[12] SHIMAMOTO H, TSUJIMOTO T, KAKIMOTO N, et al. Effectiveness of the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique for reducing motion artifacts caused by mandibular movements on fat-suppressed T2-weighted magnetic resonance (MR) images[J]. Magn Reson Imaging, 2018, 54:1-7.
[13] JONG H L, YOUNG H C, JUNG E C, et al. Improved abdominal MRI in non-breath-holding children using a radial k-space sampling technique[J]. Pediatr Radiol, 2015, 45(6):840-846.
[14] ALKAN O, KIZILKILIÇ O, YILDIRIM T, et al. Comparison of contrast-enhanced T1-weighted FLAIR with BLADE, and spin-echo T1-weighted sequences in intracranial MRI[J]. Diagn Interv Radiol, 2009, 15(2):75-80.
[15] MÁS-ESTELLÉS F, MATEOS-FERNÁNDEZ M, CARRASCOSA-BISQUERT B, et al. Contemporary non-echo-planar diffusion-weighted imaging of middle ear cholesteatomas[J]. Radiographics, 2012, 32(4):1197-1213.
[16] DONG F, WANG Q F, ZHENG H, et al. Motion artifacts correction in MRI with navigator echo combined with compressed sensing[J]. Chinese J Magn Reson, 2015, 32(3):419-428. 董芳, 王前锋, 郑慧, 等. 结合导航回波与压缩感知进行运动伪影矫正[J]. 波谱学杂志, 2015, 32(3):419-428.
Outlines

/