Chinese Journal of Magnetic Resonance >
A Miniaturised NMR RF Probe Design with External Field-locking Channel
Received date: 2022-12-16
Online published: 2023-03-13
Temperature drift is an important factor affecting the measurement accuracy of desktop NMR spectrometers, and adding a field-locking coil to the probe to achieve field-frequency interlocking is a common means of suppressing temperature drift. In this paper, a dual-channel miniaturised RF probe with an external field-locking channel is designed based on a laboratory compact Halbach magnet. The coil diameter, height, number of turns, turn spacing and enamelled wire radius were optimized based on the solenoid structure. The optimum solenoid size was obtained with an enameled wire radius of 0.4 mm, a coil diameter and height of 8.2 mm, a turn spacing of 1.6 mm and a number of turns of 5. Based on the simulation results, the detection and field-locking coils were fabricated, and tested in conjunction with the peripheral circuitry. The results show that the crosstalk between the two coils is low, the signal-to-noise ratio of the detection channel is above 50 and the signal-to-noise ratio of the locking channel is above 20. Final field locking experiments were performed and the frequency drift of the overall system after equipping the locking field was approximately 0.2 ppm/h (1 ppm=10-6), verifying that this probe design can be applied in compact Halbach magnet-based NMR analysis facilities.
Feng WANG , Tingwei LIU , Yajie XU , Peng YU , Ya WANG , Bowen PENG , Xiaodong YANG . A Miniaturised NMR RF Probe Design with External Field-locking Channel[J]. Chinese Journal of Magnetic Resonance, 2023 , 40(3) : 332 -340 . DOI: 10.11938/cjmr20223044
| [1] | GUJAR S K, MAHESHWARI S, BJ?RKMAN-BURTSCHER I, et al. Magnetic resonance spectroscopy[J]. J Neuro-Ophthalmol, 2005, 25(3): 217-226. |
| [2] | BECKER W, BHATTIPROLU K C, GUBENS?K N, et al. Investigating protein-ligand interactions by solution nuclear magnetic resonance spectroscopy[J]. Chem Phys Chem, 2018, 19(8): 895-906. |
| [3] | NEAR J, HARRIS A D, JUCHEM C, et al. Preprocessing, analysis and quantification in single-voxel magnetic resonance spectroscopy: experts’ consensus recommendations[J]. NMR Biomed, 2021, 34(5): e4257. |
| [4] | VIGNALI C, CALIGIANI A, PALLA G. Quantitative 2H NMR spectroscopy with 1H lock extender[J]. J Magn Reson, 2007, 187(1): 120-125. |
| [5] | WANG Y, XU Y, WANG F, et al. A passive shimming method for Halbach magnet based on magnetic sheet arrays[J]. J Magn Reson, 2022, 339: 107210. |
| [6] | XU Y, WANG F, WANG Y, et al. Active shim coils design for Halbach magnet based on inverse boundary element method[J]. Magn Reson Lett, 2022, 2(3): 159-169. |
| [7] | XU Y, YU P, JIA F, et al. A spherical harmonics decomposition method (SHDM) for irregular matrix coils design[J]. IEEE T Biomed Eng, 2021, 69(4): 1292-1301. |
| [8] | CHEN S, XU L, WANG H, et al. Field-frequency lock approach for 21.3-MHz high-performance NMR relaxation analyzer[J]. Aip Adv, 2018, 8(7): 075327. |
| [9] | VAN BEEK T A. Low-field benchtop NMR spectroscopy: status and prospects in natural product analysis[J]. Phytochem Analysis, 2021, 32(1): 24-37. |
| [10] | SINGH K, BLüMICH B. NMR spectroscopy with compact instruments[J]. TrAC Trend Anal Chem, 2016, 83: 12-26. |
| [11] | HALBACH K. Design of permanent multipole magnets with oriented rare earth cobalt material[J]. Nucl Instrum Meth, 1980, 169(1): 1-10. |
| [12] | TROUT S R. Use of Helmholtz coils for magnetic measurements[J]. IEEE T Magn, 1988, 24(4): 2108-2111. |
| [13] | HOULT D I, LAUTERBUR P C. The sensitivity of the zeugmatographic experiment involving human samples[J]. J Magn Reson, 1979, 34(2): 425-433. |
| [14] | MINARD K R, WIND R A. Solenoidal microcoil design—Part I: Optimizing RF homogeneity and coil dimensions[J]. Concept Magn Reson, 2001, 13(2): 128-142. |
| [15] | MINARD K R, WIND R A. Solenoidal microcoil design—Part II: Optimizing winding parameters for maximum signal-to-noise performance[J]. Concept Magn Reson, 2001, 13(3): 190-210. |
| [16] | HOULT D I, RICHARDS R E. The signal-to-noise ratio of the nuclear magnetic resonance experiment[J]. J Magn Reson, 1976, 24(1): 71-85. |
| [17] | MEDHURST R. High frequency resistance and self-capacitance of single-layer solenoids[J]. Wireless Engineer, 1947, 35-43. |
| [18] | GRUBER B, FROELING M, LEINER T, et al. RF coils: A practical guide for nonphysicists[J]. J Magn Reson Imaging, 2018, 48(3): 590-604. |
| [19] | MISPELTER J, LUPU M, BRIGUET A. NMR probeheads for biophysical and biomedical experiments: theoretical principles and practical guidelines[M]. World Scientific Publishing Company, 2015. |
| [20] | WANG Y, XU Y, WANG F, et al. A passive shimming method for Halbach magnet based on magnetic sheet arrays[J]. J Magn Reson, 2022, 339: 107210. |
| [21] | KANG K, XU Y J, ZHANG W W, et al. Low noise pre-amplifier design for low-field magnetic resonance systems[J]. Chinese J Magn Reson, 2017, 34(3): 383-395. |
| [21] | 亢科, 徐雅洁, 张闻文, 等. 低场磁共振系统的低噪声前置放大器研究设计[J]. 波谱学杂志, 2017, 34(3): 383-395. |
/
| 〈 |
|
〉 |