Future of Ultra High Field MRI in Basic Research and Clinical Applications

  • YANG Bao-lian*
Expand
  • Global MR R&D, Philips Healthcare, Cleveland, OH 44143, USA
*Corresponding author: YANG Bao-lian, Tel: 001-440-4831054, E-mail: Baolian.yang@philips.com.

Received date: 2015-03-06

  Revised date: 2015-10-22

  Online published: 2015-12-05

Supported by


Abstract

Since the first generation ultra high field MRI systems were installed around 1990, ultra high field MRI has become one of the hottest research areas in the international community of magnetic resonance in medicine, due to the benefits of higher signal-to-noise ratio (SNR), better contrast, stronger blood oxygenation level dependent (BOLD) effect and increased spectral dispersion. In this review, the structure of latest 7.0 T whole body MRI system is briefly introduced, and the research progresses of ultra high field MRI and its future in medicine, neuroscience and cognitive science are also discussed.

Cite this article

YANG Bao-lian* . Future of Ultra High Field MRI in Basic Research and Clinical Applications
[J]. Chinese Journal of Magnetic Resonance, 2015
, 32(4) : 707 -714 . DOI: 10.11938/cjmr20150416

References

 


[1]          Lauterbur P C. Image formation by induced local interactions: Examples of employing nuclear magnetic resonance[J]. Nature, 1973, 242(5 379): 190-191.

[2]          Edelstein W A, Glover G H, Hardy C J, et al. The intrinsic signal-to-noise ratio in NMR imaging[J]. Magn Reson Med, 1986, 3(4): 604-618.

[3]          Schild H. Clinical high field MR[J]. Rofo, 2005, 177: 621-631.

[4]          Okada T, Yamada H, Ito H, et al. Magnetic field strength increase yields significantly greater contrast-to-noise ratio increase: Measured using BOLD contrast in the primary visual area[J]. Acad Radiol, 2005, 12(2): 142-147.

[5]          U?urbil K, Garwood M, Ellermann J, et al. Imaging at high magnetic fields: initial experiences at 4 T [J]. Magn Reson Q, 1994, 9(4): 259-277.

[6]          Ibrahim T S, Lee R, Abduljalil A M, et al. Dielectric resonances and B1 field inhomogeneity in UHFMRI: computational analysis and experimental findings[J]. Magn Reson Imaging, 2001, 19(2): 219-226.

[7]          Hennig J. Ultra high field MR: Useful instruments or toys for the boys?[J]. Magn Reson Mater Phy, 2008, 21(1): 1-3.

[8]          SIEMENS: Magnetom 7 T brochure[OL]. https://www.siemens.com/7 T-MRI

[9]          Vaughan J T, Adriany G, Snyder C J, et al. Efficient high-frequency body coil for high-field MRI[J]. Magn Reson Med, 2004, 52(4): 851-859.

[10]       Nova Medical[OL]. http://www.novamedical.com.

Quality Electrodynamics[OL]. http://www.qualedyn.com.

[11]       Adriany G, Auerbach E J, Snyder C J, et al. A 32-Channel lattice transmission line array for parallel transmit and receive MRI at 7 Tesla[J]. Magn Reson Med, 2010, 63(6): 1 478-1 485.

[12]       Snyder C, DelaBarre L, Moeller S, et al. Comparison between eight- and sixteen-channel TEM transceive arrays for body imaging at 7 Tesla[J]. Magn Reson Med, 2012, 67(4): 954-964.

[13]       Mao M, Smith M B, Collins C M. Exploring the limits of RF shimming for high-field MRI of the human head[J]. Magn Reson Med, 2006, 56(4): 918-922.

[14]       Collins C M, Liu W, Wang J, et al. Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz[J]. J Magn Reson Imaging, 2004, 19(5): 650-656.

[15]       United States Food and Drug Administration. Guidance for Industry and FDA Staff: Criteria for Significant Risk Investigations of Magnetic Resonance Diagnostic Devices[M]. Washington DC: Food and Drug Administration, 2003.

[16]       Theysohn J M, Maderwald S, Kraff O, et al. Subjective acceptance of 7 Tesla MRI for human imaging[J]. Magn Reson Mater Phy, 2008, 21(1): 63-72.

[17]       Conijn M M, Geerlings M I, Luijten P R, et al. Visualization of cerebral microbleeds with dual-echo T2*-weighted magnetic resonance imaging at 7.0 T [J]. J Magn Reson Imaging, 2010, 32(1): 52-59.

[18]       Polders D L, Leemans A, Hendrikse J, et al. Signal to noise ratio and uncertainty in diffusion tensor imaging at 1.5, 3.0, and 7.0 Tesla[J]. J Magn Reson Imaging, 2011, 33(6): 1 456-1 463.

[19]       Grossman E J, Zhang K, An J, et al. Human brain perfusion MRI at 7 T using a segmented true FISP ASL method[J]. Proc Intl Soc Mag Reson Med, 2008, 16: 1 918.

[20]       Thomas B P, Welch E B, Niederhauser B D, et al. High-resolution 7 T MRI of the human hippocampus in vivo[J]. J Magn Reson Imaging, 2008, 28(5): 1 266-1 272.

[21]       Thürlinga M, Küpera M, Stefanescua R, et al. Activation of the dentate nucleus in a verb generation task: A 7 T MRI study[J]. NeuroImage, 2011, 57(3): 1 184-1 191.

[22]       Sanchez-Panchuelo R M, Francis S, Bowtell R, et al. Mapping human somatosensory cortex in individual subjects with 7 T functional MRI[J]. J Neurophysiol, 2010, 103(5): 2 544-2 556.

[23]       Metcalf M, Xu D, Okuda D T, et al. High-resolution phased-array MRI of the human brain at 7 Tesla: Initial experience in multiple sclerosis patients[J]. J Neuroimaging, 2010, 20(2): 141-147.

[24]       Kang C K, Park C A, Lee H, et al. Hypertension correlates with lenticulostriate arteries visualized by 7 T magnetic resonance angiography[J]. Hypertension, 2009, 54(5): 1 050-1 056.

[25]       Kerchner G A. Ultra-high field 7 T MRI: a new tool for studying Alzheimer's disease[J]. J Alzheimers Dis, 2011, 26(S3): 91-95.

[26]       van den Bogaard S J, Dumas E M, Teeuwisse W M, et al. Exploratory 7 Tesla magnetic resonance spectroscopy in Huntington's disease provides in vivo evidence for impaired energy metabolism[J]. J Neurol, 2011, 258(12): 2 230-2 239.

[27]       Henry T R, Chupin M, Lehéricy S, et al. Hippocampal sclerosis in temporal lobe epilepsy: findings at 7 T [J]. Radiology, 2011, 261(1): 199-209.

[28]       Pinker K, Bogner W, Baltzer P, et al. Clinical application of bilateral high temporal and spatial resolution dynamic contrast-enhanced magnetic resonance imaging of the breast at 7 T [J]. European Radiology, 2013, 24 (4): 913-920.

[29]       Korteweg M A, Veldhuis W B, Mali W P, et al. Investigation of lipid composition of dissected sentinel lymph nodes of breast cancer patients by 7 T proton MR spectroscopy[J]. J Magn Reson Imaging, 2012, 35(2): 387-392.

[30]       Ren J, Lakoski S, Haller R G, et al. Dynamic monitoring of carnitine and acetylcarnitine in the trimethylamine signal after exercise in human skeletal muscle by 7 T 1H-MRS[J]. Magn Reson Med, 2013, 69(1): 7-17.

[31]       Ren J, Sherry A D, Malloy C R. Noninvasive monitoring of lactate dynamics in human forearm muscle after exhaustive exercise by 1H-magnetic resonance spectroscopy at 7 Tesla[J]. Magn Reson Med, 2013, 70(3): 610-619.

[32]       Cho Z H, Min H K, Oh S H, et al. Direct visualization of deep brain stimulation targets in Parkinson disease with the use of 7 Tesla magnetic resonance imaging[J]. J Neurosurg, 2010, 113(3): 639-647.

[33]       Abosch A, Yacoub E, Ugurbil K, et al. An assessment of current brain targets for deep brain stimulation surgery with susceptibility-weighted imaging at 7 Tesla[J]. Neurosurgery, 2010, 67(6): 1 745-1 756.

[34]       Wiggins G C, Sodickson D K. Towards clinical 7 T MRI[J]. Siemens Magnetom Flash, 2011, 1: 2-19.
Outlines

/