基于流形结构正则化的快速高质量磁共振指纹定量成像
|
李鹏, 纪雨萍, 胡悦
|
High-quality MR Fingerprinting Reconstruction Based on Manifold Structured Data Priors
|
LI Peng, JI Yuping, HU Yue
|
|
表2 不同方法在使用不同采集长度L时重建参数图的归一化均方误差(NMSE)
|
Table 2 The NMSEs of the reconstructed parameter maps by different methods using various acquisition lengths L
|
|
L | 200 | 300 | 400 | 500 | Maps | T1 | T2 | PD | T1 | T2 | PD | T1 | T2 | PD | T1 | T2 | PD | BLIP | 0.0872 | 0.3789 | 0.0321 | 0.0682 | 0.2830 | 0.0311 | 0.0564 | 0.2080 | 0.0302 | 0.0453 | 0.1549 | 0.0291 | MBIR | 0.0345 | 0.3490 | 0.0369 | 0.0344 | 0.2310 | 0.0353 | 0.0328 | 0.1524 | 0.0347 | 0.0311 | 0.1160 | 0.0318 | FLOR | 0.0208 | 0.1676 | 0.0190 | 0.0143 | 0.1067 | 0.0131 | 0.0129 | 0.0680 | 0.0128 | 0.0104 | 0.0450 | 0.0101 | SL-SP | 0.0163 | 0.1417 | 0.0108 | 0.0112 | 0.0967 | 0.0105 | 0.0108 | 0.0667 | 0.0081 | 0.0102 | 0.0429 | 0.0075 | DG-LR | 0.0167 | 0.1421 | 0.0106 | 0.0109 | 0.1013 | 0.0104 | 0.0103 | 0.0659 | 0.0073 | 0.0075 | 0.0365 | 0.0045 | MS | 0.0219 | 0.1901 | 0.0180 | 0.0149 | 0.0991 | 0.0097 | 0.0137 | 0.0653 | 0.0082 | 0.0093 | 0.0406 | 0.0048 | LLR | 0.0186 | 0.1890 | 0.0132 | 0.0134 | 0.1117 | 0.0091 | 0.0120 | 0.0659 | 0.0088 | 0.0081 | 0.0400 | 0.0046 | MS-LLR(本文方法) | 0.0146 | 0.1374 | 0.0080 | 0.0094 | 0.0864 | 0.0046 | 0.0078 | 0.0603 | 0.0040 | 0.0052 | 0.0284 | 0.0027 |
|
|
|