Silicone rubber composite insulators are widely used in the power system because of advantages such as excellent hydrophobicity, high mechanical strength and light weight. Currently the methods for accuracy and effective analysis of the aging status of the composite insulators are still lacking. Although previous studies have investigated the degradation of composite insulator shied, none of them focused on composite insulator rod sheath. To measure the aging status of rod sheath, a nuclear magnetic resonance (NMR) sensor was designed, which could be applied to arc-shaped samples. The magnet structure was optimized to have a main magnetic field distribution matching up with the curvature of the rod sheath. A flexional helical radio frequency transmission coil was designed and optimized. The sensor was applied to three kinds of rod sheath with different ages. A CPMG pulse sequence was used to acquire T2 relaxation curves of the samples, which were then subjected to an inverse Laplace transformation to obtain T2 spectrum. The result showed that the T2 of the rod sheath decreased with increasing operation time. It is concluded that the parameter T2, long mean calculated from the T2 spectrum can be used for measuring the aging status of rod sheath.
LI Jun-fang
,
WU Jia-min
,
XU Zheng
,
HUANG Qiao-lin
,
SHENG Cong-bing
,
LIU She-min
,
YE Qiang
,
FENG Pan-zeng
. An Arc-Shaped NMR Sensor:Design and Application in Measuring the Aging Status of Composite Insulator Rod Sheath[J]. Chinese Journal of Magnetic Resonance, 2017
, 34(2)
: 223
-230
.
DOI: 10.11938/cjmr20170212
[1] LIANG Y, DING L J, LI C R, et al. Primary research on the diagnosis of aging silicone rubber insulators using thermally stimulation current[J]. Proceedings of the CSEE, 2007, 27(21):7-12. 梁英,丁立建, 李成榕, 等. 基于热刺激电流的硅橡胶合成绝缘子老化诊断方法初探[J]. 中国电机工程学报, 2007, 27(21):7-12.
[2] CIGRÉ WORKING GROUP 22.03(convener C. de Tourreil). Worldwide service experience with HV composite insulators[J]. Electra, 2000, 191:27-43.
[3] VAILLANCOURT G H, CARIGNAN S, JEAN C. Experience with the detection of faulty composite insulators on high-voltage power lines by the electric field measurement method[J]. IEEE T Power Deliver, 1998, 13(2):661-666.
[4] LINDNER M, ELSTEIN S, LINDNER P, et al. Daylight corona discharge imager[C]. Lodon:Proc 11th International Symposium on High-Voltage Engineeing, 1999.
[5] LINDNER P. Inspection for corona and arcing with the Daycor camera[C]. Hong Kong:Proceeding of World Insulator Congress and Exhibition, 2005.
[6] PINNANGUDI B, GORUR R S, KROESE A J. Quantification of corona discharges on nonceramic insulators[J]. IEEE T Dielect El In, 2005, 12(3):513-523.
[7] ARBUSOV R S, OVSYANNIKOV A G. UV-inspection of HV equipment[C]. Beijing:Proc. 14th International Symposium on High-Voltage Engineering, 2005.
[8] STOLPER R, HART J, MAHATHO N. The design and evaluation of a multi-spectral imaging camera for the inspection of transmission lines and substations equipment[C]. Hong Kong:Proceeding of World Insulator Congress and Exhibition, 2005.
[9] SPANGENBERG E, RIQUEL G. In service diagnostic of composite insulators EDF's test results[C]. Montréal:Proc. 10th International Symposium On High-Voltage Engineering, 1997.
[10] CHEN Y, GUO J F, WU X J. Fast detection of zero insulator and polluted insulator based on infrared temperature measurement[J]. High-Voltage Apparatus, 2015, 51(6):0191-0194. 陈勇, 郭俊峰, 邬小均. 基于红外测温的零值和污秽绝缘子快速检测试验研究[J]. 高压电器, 2015, 51(6):0191-0194.
[11] PHILLIPS J, MELAIA R. Ultrasonic emission from nonceramic insulators with defects[C]. London:Proc. 11th International Symposium On High-Voltage Engineering, 1999.
[12] MAEV R G, LEVIN V M, MAEVA E Y, et al. Comparison between scanning acoustic microscopy and submillimeter spectroscopy-A new opportunity to investigate dielectric behavior and structure of materials[C]. Millbrae:IEEE Conference on Electrical Insulation and Dielectric Phenomena, 1996.
[13] CHENG Y C, LI C R. Online detecting composite insulators by two dimensions electric field cistribution[C]. Toronto:IEEE International Symposium On Electrical Insulation, 2006.
[14] VOLAT C, JABBARI M, FARZANEH M, et al. New method for in live-line detection of small defects in composite insulator based on electro-optic e-field sensor[J]. IEEE T Dielect El In, 2013, 20(1):194-201.
[15] BERG M, THOTTAPPILLIL R, SCUKA V. Hydrophobicity estimation of HV polymeric insulating[J]. IEEE T Dielect El In, 2001, 8(6):1089-1107.
[16] TOKORO T, NAGAO M, KOSAKI M. Image analysis of hydrophobicity of polymer insulators by observing at microscopic area[C]. Victoria:IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2000.
[17] TOKORO T, OMOTO Y, KOSAKI M. Image analysis of hydrophobicity of polymer insulators using PVM[C]. Kitchener:IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2001.
[18] 高雅琦. 基于声发射的外绝缘状态检测研究[D]. 天津:天津大学, 2012.
[19] GUBANSKI S M, DERNFALK1 A, ANDERSSON J, et al. Diagnostic methods for outdoor polymeric insulators[J]. IEEE T Dielect El In, 2007, 14(5):1065-1080.
[20] XU Z, ZHAO S J, GUO P. A portable NMR sensor used for assessing the aging status of silicone rubber insulator[J]. Appl Magn Reson, 2013, 44(12):1405-1417.
[21] LIANG X D, DAI J F. Analysis of the acid sources of a field brittle fractured composite insulator[J]. IEEE T Dielect El In, 2006, 13(4):870-876.
[22] JÖRG M, FEDERICO C, BERNHARD B. Shaping the sensitive volume of a single-sided NMR-sensor to profile cylindrical samples with high resolution[J]. Appl Magn Reson, 2013, 44(11):1325-1334.
[23] PAULSEN J L, BOUCHARD L S, GRAZIANI D, et al. Volume-selective magnetic resonance imaging using an adjustable, single-sided, portable sensor[J]. Proc Natl Acad Sci USA, 2008, 105(52):20601-20604.
[24] 何晓龙. 开放式核磁共振磁体设计的并行计算方法研究[D]. 重庆:重庆大学, 2013.
[25] ANDREW E M. Magnets for unilateral magnetic resonance[D]. Canada:University of New Brunswick, 2007.