Chinese Journal of Magnetic Resonance ›› 2017, Vol. 34 ›› Issue (2): 223-230.doi: 10.11938/cjmr20170212
Previous Articles Next Articles
LIU She-min1, YE Qiang2, HUANG Qiao-lin1, SHENG Cong-bing1, FENG Pan-zeng1, LI Jun-fang1, WU Jia-min2, XU Zheng2
Received:
2016-07-22
Revised:
2017-04-18
Published:
2017-06-05
Online:
2017-06-05
CLC Number:
LIU She-min, YE Qiang, HUANG Qiao-lin, SHENG Cong-bing, FENG Pan-zeng, LI Jun-fang, WU Jia-min, XU Zheng. An Arc-Shaped NMR Sensor:Design and Application in Measuring the Aging Status of Composite Insulator Rod Sheath[J]. Chinese Journal of Magnetic Resonance, 2017, 34(2): 223-230.
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
[1] LIANG Y, DING L J, LI C R, et al. Primary research on the diagnosis of aging silicone rubber insulators using thermally stimulation current[J]. Proceedings of the CSEE, 2007, 27(21):7-12. 梁英,丁立建, 李成榕, 等. 基于热刺激电流的硅橡胶合成绝缘子老化诊断方法初探[J]. 中国电机工程学报, 2007, 27(21):7-12. [2] CIGRÉ WORKING GROUP 22.03(convener C. de Tourreil). Worldwide service experience with HV composite insulators[J]. Electra, 2000, 191:27-43. [3] VAILLANCOURT G H, CARIGNAN S, JEAN C. Experience with the detection of faulty composite insulators on high-voltage power lines by the electric field measurement method[J]. IEEE T Power Deliver, 1998, 13(2):661-666. [4] LINDNER M, ELSTEIN S, LINDNER P, et al. Daylight corona discharge imager[C]. Lodon:Proc 11th International Symposium on High-Voltage Engineeing, 1999. [5] LINDNER P. Inspection for corona and arcing with the Daycor camera[C]. Hong Kong:Proceeding of World Insulator Congress and Exhibition, 2005. [6] PINNANGUDI B, GORUR R S, KROESE A J. Quantification of corona discharges on nonceramic insulators[J]. IEEE T Dielect El In, 2005, 12(3):513-523. [7] ARBUSOV R S, OVSYANNIKOV A G. UV-inspection of HV equipment[C]. Beijing:Proc. 14th International Symposium on High-Voltage Engineering, 2005. [8] STOLPER R, HART J, MAHATHO N. The design and evaluation of a multi-spectral imaging camera for the inspection of transmission lines and substations equipment[C]. Hong Kong:Proceeding of World Insulator Congress and Exhibition, 2005. [9] SPANGENBERG E, RIQUEL G. In service diagnostic of composite insulators EDF's test results[C]. Montréal:Proc. 10th International Symposium On High-Voltage Engineering, 1997. [10] CHEN Y, GUO J F, WU X J. Fast detection of zero insulator and polluted insulator based on infrared temperature measurement[J]. High-Voltage Apparatus, 2015, 51(6):0191-0194. 陈勇, 郭俊峰, 邬小均. 基于红外测温的零值和污秽绝缘子快速检测试验研究[J]. 高压电器, 2015, 51(6):0191-0194. [11] PHILLIPS J, MELAIA R. Ultrasonic emission from nonceramic insulators with defects[C]. London:Proc. 11th International Symposium On High-Voltage Engineering, 1999. [12] MAEV R G, LEVIN V M, MAEVA E Y, et al. Comparison between scanning acoustic microscopy and submillimeter spectroscopy-A new opportunity to investigate dielectric behavior and structure of materials[C]. Millbrae:IEEE Conference on Electrical Insulation and Dielectric Phenomena, 1996. [13] CHENG Y C, LI C R. Online detecting composite insulators by two dimensions electric field cistribution[C]. Toronto:IEEE International Symposium On Electrical Insulation, 2006. [14] VOLAT C, JABBARI M, FARZANEH M, et al. New method for in live-line detection of small defects in composite insulator based on electro-optic e-field sensor[J]. IEEE T Dielect El In, 2013, 20(1):194-201. [15] BERG M, THOTTAPPILLIL R, SCUKA V. Hydrophobicity estimation of HV polymeric insulating[J]. IEEE T Dielect El In, 2001, 8(6):1089-1107. [16] TOKORO T, NAGAO M, KOSAKI M. Image analysis of hydrophobicity of polymer insulators by observing at microscopic area[C]. Victoria:IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2000. [17] TOKORO T, OMOTO Y, KOSAKI M. Image analysis of hydrophobicity of polymer insulators using PVM[C]. Kitchener:IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2001. [18] 高雅琦. 基于声发射的外绝缘状态检测研究[D]. 天津:天津大学, 2012. [19] GUBANSKI S M, DERNFALK1 A, ANDERSSON J, et al. Diagnostic methods for outdoor polymeric insulators[J]. IEEE T Dielect El In, 2007, 14(5):1065-1080. [20] XU Z, ZHAO S J, GUO P. A portable NMR sensor used for assessing the aging status of silicone rubber insulator[J]. Appl Magn Reson, 2013, 44(12):1405-1417. [21] LIANG X D, DAI J F. Analysis of the acid sources of a field brittle fractured composite insulator[J]. IEEE T Dielect El In, 2006, 13(4):870-876. [22] JÖRG M, FEDERICO C, BERNHARD B. Shaping the sensitive volume of a single-sided NMR-sensor to profile cylindrical samples with high resolution[J]. Appl Magn Reson, 2013, 44(11):1325-1334. [23] PAULSEN J L, BOUCHARD L S, GRAZIANI D, et al. Volume-selective magnetic resonance imaging using an adjustable, single-sided, portable sensor[J]. Proc Natl Acad Sci USA, 2008, 105(52):20601-20604. [24] 何晓龙. 开放式核磁共振磁体设计的并行计算方法研究[D]. 重庆:重庆大学, 2013. [25] ANDREW E M. Magnets for unilateral magnetic resonance[D]. Canada:University of New Brunswick, 2007. |
[1] | LIU Ying, YUAN Binhua, ZHANG Haowei. Design of a Portable Magnetic Resonance Multi-source RF Pulse Generator [J]. Chinese Journal of Magnetic Resonance, 2025, 42(3): 285-298. |
[2] | JIANG Chaochao, YAO Shouquan, XU Juncheng, JIANG Yu. Design of the Broadband Magnetic Resonance Microcoil [J]. Chinese Journal of Magnetic Resonance, 2025, 42(3): 299-307. |
[3] | SHU Wei. Diagnostic Efficacy Comparison of B-scan Ultrasonography and MRI in Fetal Skeletal Abnormalities [J]. Chinese Journal of Magnetic Resonance, 2025, 42(3): 265-274. |
[4] | SUI Meiju, ZHANG Lei, WANG Ruifang, LUO Yingying, LI Sha, QIU Maosong, XU Qiuyi, CHEN Daiqin, CHEN Shizhen, ZHOU Xin. MRI-traceable Nanoenzyme for Cascade Catalysis-enhanced Immunotherapy [J]. Chinese Journal of Magnetic Resonance, 2025, 42(3): 231-248. |
[5] | KOU Xinhui, ZHANG Yubing. Study on the Enantiomeric Recognition of Chiral Ureas Containing Amino Acid Units [J]. Chinese Journal of Magnetic Resonance, 2025, 42(3): 221-230. |
[6] | MA Yingxue, ZHAO Yanqiang, YANG Xiaodong, JIANG Bin, TAO Cheng. Opportunities and Challenges of High-field and Ultra-high-field Magnetic Resonance Imaging in China [J]. Chinese Journal of Magnetic Resonance, 2025, 42(3): 334-344. |
[7] | LI Keyan, CHENG Xin, CHEN Junfei, CAO Li, HUANG Zhen, LIU Chaoyang. Development of Low-noise Preamplifier for Low-field NMR [J]. Chinese Journal of Magnetic Resonance, 2025, 42(3): 321-333. |
[8] | TANG Shihao, YANG Jinyu, XU Yajie, WANG Ya, PENG Bowen, GAO Yuhao, YANG Xiaodong. A Design of Circularly Polarized Coil for Low-field Nuclear Magnetic Resonance Spectrometers [J]. Chinese Journal of Magnetic Resonance, 2025, 42(3): 308-320. |
[9] | HE Fengcheng, LI Mingdao, LV Xinglong, YAO Shouquan, JIANG Yu. Software Design of the Handheld NMR Spectrometer Console [J]. Chinese Journal of Magnetic Resonance, 0, (): 0-0. |
[10] | . Structural Identification and Complete NMR Spectral Assignments of 4-Isopropoxy-1-(trifluoroacetyl)naphthalene [J]. Chinese Journal of Magnetic Resonance, 0, (): 0-0. |
[11] | CHEN Bo, LIU Quan, MA Lei, CHEN Shunian, JIA Yaqi, ZHU Bin, GUO Junwang. Simulink-based Simulation Study of Continuous Wave Electron Paramagnetic Resonance Signal Processing and Detection [J]. Chinese Journal of Magnetic Resonance, 2025, 42(2): 174-183. |
[12] | GU Jiajia, WANG Yuanjun. Hybrid Attention and Multiscale Module for Alzheimer's Disease Classification [J]. Chinese Journal of Magnetic Resonance, 2025, 42(2): 103-116. |
[13] | ZUO Bingyu, SHI Lili, SONG Jia, ZHAO Yang, LI Qian. Application of Estrogen and Tumor Markers Combined with DCE-MRI in Diagnosis and Clinical Staging of Cervical Cancer [J]. Chinese Journal of Magnetic Resonance, 2025, 42(2): 164-173. |
[14] | SUN Haoyun, WANG Lijia. Application of 3D ELD_MobileNetV2 Incorporating Attention Mechanism and Dilated Convolution in Hepatic Nodules Classification [J]. Chinese Journal of Magnetic Resonance, 2025, 42(2): 130-142. |
[15] | WEI Zhihong, KONG Xudong, KONG Yan, YAN Shiju, DING Yang, WEI Xianding, KONG Dong, YANG Bo. Application of Generative Adversarial Networks Based on Global and Local Feature Information in Hippocampus Segmentation [J]. Chinese Journal of Magnetic Resonance, 2025, 42(2): 143-153. |
Viewed | ||||||
Full text |
|
|||||
Abstract |
|
|||||