Chinese Journal of Magnetic Resonance ›› 2017, Vol. 34 ›› Issue (2): 223-230.doi: 10.11938/cjmr20170212
Previous Articles Next Articles
LIU She-min1, YE Qiang2, HUANG Qiao-lin1, SHENG Cong-bing1, FENG Pan-zeng1, LI Jun-fang1, WU Jia-min2, XU Zheng2
Received:2016-07-22
Revised:2017-04-18
Published:2017-06-05
Online:2017-06-05
CLC Number:
LIU She-min, YE Qiang, HUANG Qiao-lin, SHENG Cong-bing, FENG Pan-zeng, LI Jun-fang, WU Jia-min, XU Zheng. An Arc-Shaped NMR Sensor:Design and Application in Measuring the Aging Status of Composite Insulator Rod Sheath[J]. Chinese Journal of Magnetic Resonance, 2017, 34(2): 223-230.
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
| [1] LIANG Y, DING L J, LI C R, et al. Primary research on the diagnosis of aging silicone rubber insulators using thermally stimulation current[J]. Proceedings of the CSEE, 2007, 27(21):7-12. 梁英,丁立建, 李成榕, 等. 基于热刺激电流的硅橡胶合成绝缘子老化诊断方法初探[J]. 中国电机工程学报, 2007, 27(21):7-12. [2] CIGRÉ WORKING GROUP 22.03(convener C. de Tourreil). Worldwide service experience with HV composite insulators[J]. Electra, 2000, 191:27-43. [3] VAILLANCOURT G H, CARIGNAN S, JEAN C. Experience with the detection of faulty composite insulators on high-voltage power lines by the electric field measurement method[J]. IEEE T Power Deliver, 1998, 13(2):661-666. [4] LINDNER M, ELSTEIN S, LINDNER P, et al. Daylight corona discharge imager[C]. Lodon:Proc 11th International Symposium on High-Voltage Engineeing, 1999. [5] LINDNER P. Inspection for corona and arcing with the Daycor camera[C]. Hong Kong:Proceeding of World Insulator Congress and Exhibition, 2005. [6] PINNANGUDI B, GORUR R S, KROESE A J. Quantification of corona discharges on nonceramic insulators[J]. IEEE T Dielect El In, 2005, 12(3):513-523. [7] ARBUSOV R S, OVSYANNIKOV A G. UV-inspection of HV equipment[C]. Beijing:Proc. 14th International Symposium on High-Voltage Engineering, 2005. [8] STOLPER R, HART J, MAHATHO N. The design and evaluation of a multi-spectral imaging camera for the inspection of transmission lines and substations equipment[C]. Hong Kong:Proceeding of World Insulator Congress and Exhibition, 2005. [9] SPANGENBERG E, RIQUEL G. In service diagnostic of composite insulators EDF's test results[C]. Montréal:Proc. 10th International Symposium On High-Voltage Engineering, 1997. [10] CHEN Y, GUO J F, WU X J. Fast detection of zero insulator and polluted insulator based on infrared temperature measurement[J]. High-Voltage Apparatus, 2015, 51(6):0191-0194. 陈勇, 郭俊峰, 邬小均. 基于红外测温的零值和污秽绝缘子快速检测试验研究[J]. 高压电器, 2015, 51(6):0191-0194. [11] PHILLIPS J, MELAIA R. Ultrasonic emission from nonceramic insulators with defects[C]. London:Proc. 11th International Symposium On High-Voltage Engineering, 1999. [12] MAEV R G, LEVIN V M, MAEVA E Y, et al. Comparison between scanning acoustic microscopy and submillimeter spectroscopy-A new opportunity to investigate dielectric behavior and structure of materials[C]. Millbrae:IEEE Conference on Electrical Insulation and Dielectric Phenomena, 1996. [13] CHENG Y C, LI C R. Online detecting composite insulators by two dimensions electric field cistribution[C]. Toronto:IEEE International Symposium On Electrical Insulation, 2006. [14] VOLAT C, JABBARI M, FARZANEH M, et al. New method for in live-line detection of small defects in composite insulator based on electro-optic e-field sensor[J]. IEEE T Dielect El In, 2013, 20(1):194-201. [15] BERG M, THOTTAPPILLIL R, SCUKA V. Hydrophobicity estimation of HV polymeric insulating[J]. IEEE T Dielect El In, 2001, 8(6):1089-1107. [16] TOKORO T, NAGAO M, KOSAKI M. Image analysis of hydrophobicity of polymer insulators by observing at microscopic area[C]. Victoria:IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2000. [17] TOKORO T, OMOTO Y, KOSAKI M. Image analysis of hydrophobicity of polymer insulators using PVM[C]. Kitchener:IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2001. [18] 高雅琦. 基于声发射的外绝缘状态检测研究[D]. 天津:天津大学, 2012. [19] GUBANSKI S M, DERNFALK1 A, ANDERSSON J, et al. Diagnostic methods for outdoor polymeric insulators[J]. IEEE T Dielect El In, 2007, 14(5):1065-1080. [20] XU Z, ZHAO S J, GUO P. A portable NMR sensor used for assessing the aging status of silicone rubber insulator[J]. Appl Magn Reson, 2013, 44(12):1405-1417. [21] LIANG X D, DAI J F. Analysis of the acid sources of a field brittle fractured composite insulator[J]. IEEE T Dielect El In, 2006, 13(4):870-876. [22] JÖRG M, FEDERICO C, BERNHARD B. Shaping the sensitive volume of a single-sided NMR-sensor to profile cylindrical samples with high resolution[J]. Appl Magn Reson, 2013, 44(11):1325-1334. [23] PAULSEN J L, BOUCHARD L S, GRAZIANI D, et al. Volume-selective magnetic resonance imaging using an adjustable, single-sided, portable sensor[J]. Proc Natl Acad Sci USA, 2008, 105(52):20601-20604. [24] 何晓龙. 开放式核磁共振磁体设计的并行计算方法研究[D]. 重庆:重庆大学, 2013. [25] ANDREW E M. Magnets for unilateral magnetic resonance[D]. Canada:University of New Brunswick, 2007. |
| [1] | LIU Ying, LV Hailong, LU Zhihao, ZHANG Haowei. Design of a Low-sampling-rate MRI Receiver [J]. Chinese Journal of Magnetic Resonance, 2026, 43(3): 241-252. |
| [2] | LIU Wanzhen, CHEN Fang, CHEN Li, WANG Jiaxin, CHENG Xin, YI Peng, ZHANG Zhi, LIU Chaoyang. Research on Large-bore and High Homogeneity Halbach Magnet for Nuclear Magnetic Resonance [J]. Chinese Journal of Magnetic Resonance, 2026, 43(3): 253-267. |
| [3] | LU Xingyun, YAO Shouquan, XU Juncheng, JIANG Yu. A High-stability Shimming Current Amplifier Design for Low-field Permanent Magnet NMR Systems [J]. Chinese Journal of Magnetic Resonance, 2026, 43(3): 268-278. |
| [4] | LI Na, XIAO Long, LI Sha, LIU Yudun, JIA Yushu, ZHANG Lei, CHEN Shizhen. 19F NMR Chemical Shift-encoded cRGD-targeted Dual-modal Probe for Multicolor Imaging [J]. Chinese Journal of Magnetic Resonance, 2026, 43(3): 279-290. |
| [5] | YANG Jingjing, WANG Yuanjun. Deformable Registration Network Based on Multi-scale Dilated Residual and Dual Attention [J]. Chinese Journal of Magnetic Resonance, 2026, 43(3): 291-306. |
| [6] | LIU Kewen, JIANG Yukang, CHEN Fang, CHEN Junfei, LU Yuan, CHEN Li, LIU Chaoyang. A Deep Learning-based Method for LF-NMR Relaxation Time Spectrum Inversion [J]. Chinese Journal of Magnetic Resonance, 2026, 43(3): 307-320. |
| [7] | SU Yilin, LIU Yuanyuan, CUI Zhuoxu, LIANG Dong. Physics Guided Multi-contrast Magnetic Resonance Reconstruction Diffusion Model [J]. Chinese Journal of Magnetic Resonance, 2026, 43(3): 321-338. |
| [8] | PAN Meihong, QIN Nan, ZHAO Chuan, WEN Liujing. Detailed NMR Assignment of Ensifentrine [J]. Chinese Journal of Magnetic Resonance, 2026, 43(3): 339-349. |
| [9] | XIE Yaxin, YANG Yin, SU Xuncheng. Applications of Pulsed Dipolar EPR Spectroscopy in Characterizing Interactions and Structural Changes of Biomacromolecules [J]. Chinese Journal of Magnetic Resonance, 2026, 43(3): 350-366. |
| [10] | MA Suchao, WANG Yuanjun. Research Progress on Diffusion Magnetic Resonance Imaging Noise Reduction Methods Based on Deep Learning [J]. Chinese Journal of Magnetic Resonance, 2026, 43(3): 367-388. |
| [11] | LI Xueting, LIANG Wei, ZHANG Xintong, CUI Mengqi, LIN Yulan. Resolving Crowded NMR Spectra Based on Longitudinal Multi-spin Order and Hadamard Encoding [J]. Chinese Journal of Magnetic Resonance, 2026, 43(2): 125-135. |
| [12] | WANG Jing, XIAO Yao, YU Xin, YI Xianfeng, ZHENG Anmin. Influence Mechanism of NH4F Etching on the Structure and Acidity of ZSM-5 Zeolite [J]. Chinese Journal of Magnetic Resonance, 2026, 43(2): 136-145. |
| [13] | LIU Jia, WANG Yingxiong, ZHAO Jiancheng. NMR Study of Tautomeric Distribution of Monosaccharides in Imidazolyl Ionic Liquids/DMSO-d6 [J]. Chinese Journal of Magnetic Resonance, 2026, 43(2): 146-163. |
| [14] | GAO Yuan, LIU Xinyue, WANG Sihong, HU Wei. Structure Elucidation of cis- and trans-1,2,4-Oxadiazol Derivatives [J]. Chinese Journal of Magnetic Resonance, 2026, 43(2): 164-174. |
| [15] | CAI Yue, WANG Xuxia, LIU Sijie, GUO Haodong, CHEN Xi, CHENG Linlin, KANG Yan, LIN Fuchun. Magnetic Resonance Imaging Study on the Microstructure Abnormalities of Striatal White Matter in Type 2 Diabetic Mellitus Rats [J]. Chinese Journal of Magnetic Resonance, 2026, 43(2): 175-185. |
| Viewed | ||||||
|
Full text |
|
|||||
|
Abstract |
|
|||||