Chinese Journal of Magnetic Resonance ›› 2023, Vol. 40 ›› Issue (4): 397-409.doi: 10.11938/cjmr20233058
• Articles • Previous Articles Next Articles
ZHOU Tianli1,2,ZHANG Dian3,WU Jizhi3,JIA Huihui3,CHANG Yan2,SHENG Mao3,*(
),YANG Xiaodong1,2,#(
)
Received:2023-03-06
Published:2023-12-05
Online:2023-03-31
Contact:
* Tel: 13915518071, E-mail: CLC Number:
ZHOU Tianli, ZHANG Dian, WU Jizhi, JIA Huihui, CHANG Yan, SHENG Mao, YANG Xiaodong. Application of MRI-based Finite Element Modeling and Analysis in Periacetabular Osteotomy[J]. Chinese Journal of Magnetic Resonance, 2023, 40(4): 397-409.
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
| [1] | YANG S, ZUSMAN N, LIEBERMAN E, et al. Developmental dysplasia of the hip[J]. Pediatrics, 2019, 143(1). |
| [2] | Wu M D, Feng J, Jia H H, et al. MRI-based morphological quantification of developmental dysplasia of the hip in children[J]. Chinese J Magn Reson, 2020, 37(4): 434-446. |
| 吴明娣, 冯洁, 贾慧惠, 等. 儿童发育性髋关节脱位的磁共振形态学定量[J]. 波谱学杂志, 2020, 37(4): 434-446. | |
| [3] |
GANZ R, KLAUE K, VINH T S, et al. A new periacetabular osteotomy for the treatment of hip dysplasias. Technique and preliminary results[J]. Clin Orthop Relat R, 1988, (232): 26-36.
pmid: 3383491 |
| [4] |
HAKIM N S, KING A I. A three dimensional finite element dynamic response analysis of a vertebra with experimental verification[J]. J Biomech, 1979, 12(4): 277-285 & 287-292.
pmid: 468853 |
| [5] |
TANNE K, SAKUDA M. Biomechanical and clinical changes of the craniofacial complex from orthopedic maxillary protraction[J]. Angle Orthod, 1991, 61(2): 145-152.
pmid: 2064072 |
| [6] | GAMBOA A, COSA A, BENET F, et al. A semiautomatic segmentation method, solid tissue classification and 3D reconstruction of mandible from computed tomography imaging for biomechanical analysis[C]// Barcelona, SPAIN:9th IEEE International Symposium on Biomedical Imaging (ISBI) - From Nano to Macro, 2012: 1483-1486. |
| [7] | WANG Y C, YANG D, ZHAO L H, et al. Finite element analysis of mechanical characteristics of internal fixation for treatment of proximal femoral osteolytic lesions in children[J]. Orthop Surg, 2023, 10.1111/os.13591. |
| [8] |
ZHAO X, CHOSA E, TOTORIBE K, et al. Effect of periacetabular osteotomy for acetabular dysplasia clarified by three-dimensional finite element analysis[J]. J Orthop Sci, 2010, 15(5): 632-640.
doi: 10.1007/s00776-010-1511-z pmid: 20953924 |
| [9] |
LEE K J, PARK S J, LEE S J, et al. Biomechanical study on the efficacy of the periacetabular osteotomy using patient-specific finite element analysis[J]. Int J Precis Eng Man, 2015, 16(4): 823-829.
doi: 10.1007/s12541-015-0108-z |
| [10] |
LIU L, ECKER T M, SCHUMANN S, et al. Evaluation of constant thickness cartilage models vs. patient specific cartilage models for an optimized computer-assisted planning of periacetabular osteotomy[J]. PLoS One, 2016, 11(1): e0146452.
doi: 10.1371/journal.pone.0146452 |
| [11] | PARK S J, LEE S J, CHEN W M, et al. Computer-assisted optimization of the acetabular rotation in periacetabular osteotomy using patient’s anatomy-specific finite element analysis[J]. Appl Bionics Biomech, 2018: 9730525. |
| [12] |
KITAMURA K, FUJII M, IWAMOTO M, et al. Effect of coronal plane acetabular correction on joint contact pressure in periacetabular osteotomy: a finite-element analysis[J]. BMC Musculoskelet Disord, 2022, 23(1): 48.
doi: 10.1186/s12891-022-05005-5 |
| [13] | TIAN H, XU P, LU N, et al. The effect of pelvic modeling on outcome in preoperative planning for bernese acetabular osteotomy[J]. Journal of Medical Biomechanics, 2020, 35(6): 712-717. |
| 田昊, 许平, 鲁宁, 等. Bernese髋臼截骨术术前规划中骨盆建模对结果的影响[J]. 医用生物力学, 2020, 35(6): 712-717. | |
| [14] | ZHANG L L, WANG X Y, CHEN X D. Study on finite element analysis method for the pre-operative planning of bernese periacetabular osteotomy[J]. Journal of Biomedical Engineering, 2016, 33(3): 455-460. |
| 张琳琳, 王旭义, 陈晓东. Bernese髋臼周围截骨术术前规划的有限元分析方法研究[J]. 生物医学工程学杂志, 2016, 33(3): 455-460. | |
| [15] |
STARLY B, FANG Z, SUN W, et al. Three-dimensional reconstruction for medical-CAD modeling[J]. Computer-aided Design and Applications, 2005, 2(1-4): 431-438.
doi: 10.1080/16864360.2005.10738392 |
| [16] | YANG Z G, GAN L, YE J X. Construction and stability of finite element models of distal tibial fractures[J]. Chinese Journal of Tissue Engineering Research, 2016, 20(17): 2540-2545. |
| 杨志刚, 甘霖, 叶俊星. 胫骨远端骨折有限元模型的建立及稳定性分析[J]. 中国组织工程研究, 2016, 20(17): 2540-2545. | |
| [17] |
SOWMIANARAYANAN S, CHANDRASEKARAN A, KUMAR R K. Finite element analysis of a subtrochanteric fractured femur with dynamic hip screw, dynamic condylar screw, and proximal femur nail implants - a comparative study[J]. P I Mech Eng H, 2008, 222(1): 117-127.
doi: 10.1243/09544119JEIM156 |
| [18] |
AKRAMI M, CRAIG K, DIBAJ M, et al. A three-dimensional finite element analysis of the human hip[J]. J Med Eng Technol, 2018, 42(7): 546-552.
doi: 10.1080/03091902.2019.1576795 pmid: 30875263 |
| [19] |
BERGMANN G, DEURETZBACHER G, HELLER M, et al. Hip contact forces and gait patterns from routine activities[J]. J Biomech, 2001, 34(7): 859-871.
doi: 10.1016/s0021-9290(01)00040-9 pmid: 11410170 |
| [20] |
BERGMANN G, GRAICHEN F, ROHLMANN A, et al. Hip joint forces during load carrying[J]. Clin Orthop Relat R, 1997, (335): 190-201.
pmid: 9020218 |
| [21] |
BAY B K, HAMEL A J, OLSON S A, et al. Statically equivalent load and support conditions produce different hip joint contact pressures and periacetabular strains[J]. J Biomech, 1997, 30(2): 193-196.
pmid: 9001941 |
| [22] |
PHILLIPS A T M, PANKAJ P, HOWIE C R, et al. Finite element modelling of the pelvis: inclusion of muscular and ligamentous boundary conditions[J]. Med Eng Phys, 2007, 29(7): 739-748.
pmid: 17035063 |
| [23] |
ZOU Z, CHAVEZ-ARREOLA A, MANDAL P, et al. Optimization of the position of the acetabulum in a ganz periacetabular osteotomy by finite element analysis[J]. J Orthop Res, 2013, 31(3): 472-479.
doi: 10.1002/jor.22245 pmid: 23097237 |
| [24] |
GENDA E, IWASAKI N, LI G A, et al. Normal hip joint contact pressure distribution in single-leg standing—effect of gender and anatomic parameters[J]. J Biomech, 2001, 34(7): 895-905.
doi: 10.1016/S0021-9290(01)00041-0 |
| [25] |
HARRIS M D, ANDERSON A E, HENAK C R, et al. Finite element prediction of cartilage contact stresses in normal human hips[J]. J Orthop Res, 2012, 30(7): 1133-1139.
doi: 10.1002/jor.22040 pmid: 22213112 |
| [26] | AKRAMI M, QIAN Z, ZOU Z, et al. Subject-specific finite element modelling of the human foot complex during walking: sensitivity analysis of material properties, boundary and loading conditions[J]. Biomech Mode Mechan, 2018, 17(2): 559-576. |
| [27] |
WU Z, CHEN S, LI Y, et al. Effect of centre-edge angle on clinical and quality of life outcomes after arthroscopic acetabular labral debridement[J]. Int Orthop, 2016, 40(7): 1427-1432.
doi: 10.1007/s00264-015-2923-3 pmid: 26220148 |
| [28] | KOLBER M J, CHEATHAM S W. Orthopedic management of the hip and pelvis[M]. St. Louis: Elsevier Health Sciences, 2015. |
| [29] |
WU G, SIEGLER S, ALLARD P, et al. ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion - part 1: ankle, hip, and spine[J]. J Biomech, 2002, 35(4): 543-548.
doi: 10.1016/S0021-9290(01)00222-6 |
| [30] |
XIONG B, YANG P, LIN T, et al. Changes in hip joint contact stress during a gait cycle based on the individualized modeling method of “gait-musculoskeletal system-finite element”[J]. J Orthop Surg Res, 2022, 17(1): 267.
doi: 10.1186/s13018-022-03094-5 |
| [31] | MA Y, XING C J, XIAO L. Knee joint image segmentation and model construction based on cascaded network[J]. Chinese J Magn Reson, 2022, 39(2): 184-195. |
| 马岩, 邢藏菊, 肖亮. 基于级联网络的膝关节图像分割与模型构建[J]. 波谱学杂志, 2022, 39(2): 184-195. |
| [1] | LI Na, XIAO Long, LI Sha, LIU Yudun, JIA Yushu, ZHANG Lei, CHEN Shizhen. 19F NMR Chemical Shift-encoded cRGD-targeted Dual-modal Probe for Multicolor Imaging [J]. Chinese Journal of Magnetic Resonance, 2026, 43(3): 279-290. |
| [2] | SU Yilin, LIU Yuanyuan, CUI Zhuoxu, LIANG Dong. Physics Guided Multi-contrast Magnetic Resonance Reconstruction Diffusion Model [J]. Chinese Journal of Magnetic Resonance, 2026, 43(3): 321-338. |
| [3] | CAI Yue, WANG Xuxia, LIU Sijie, GUO Haodong, CHEN Xi, CHENG Linlin, KANG Yan, LIN Fuchun. Magnetic Resonance Imaging Study on the Microstructure Abnormalities of Striatal White Matter in Type 2 Diabetic Mellitus Rats [J]. Chinese Journal of Magnetic Resonance, 2026, 43(2): 175-185. |
| [4] | LI Ruiyi, LI Sha, XU Qiuyi, SUI Meiju, CHEN Shizhen. In Situ Regulation of Protein Corona for Enhanced Tumor-targeted 19F MRI and Combined Therapy [J]. Chinese Journal of Magnetic Resonance, 2026, 43(2): 200-213. |
| [5] | XIE Xinyi, WANG Yuanjun. Research Progress on Super-resolution Reconstruction of Brain Diffusion Magnetic Resonance Images [J]. Chinese Journal of Magnetic Resonance, 2026, 43(2): 223-240. |
| [6] | FU Fenfang, LIN Guobing, LI Meifang. Advances in Magnetic Resonance Imaging for the Diagnosis and Prognosis of Mild Traumatic Brain Injury [J]. Chinese Journal of Magnetic Resonance, 2026, 43(2): 214-222. |
| [7] | WANG Yiwen, WU Guangyao, WEN Zhi, LIN Fuchun. Antiretroviral Therapy-related Alteration of Brain Functional Dynamics in People with HIV [J]. Chinese Journal of Magnetic Resonance, 2026, 43(1): 61-70. |
| [8] | NI Guangmao, LI Yuwei, HOU Wenxuan, LIU Caiyun, DONG Peng, ZHANG Yanhui. Research on the Influencing Factors of Acute Cerebral Infarction Recurrence Based on MR-DWI [J]. Chinese Journal of Magnetic Resonance, 2026, 43(1): 87-93. |
| [9] | CHEN Xi, LIU Sijie, CAI Yue, CHENG Linlin, WANG Xuxia, KANG Yan, LIN Fuchun, LEI Hao. Effects of Seizure-inducing Doses Nicotine on Hippocampal Structure in Adolescent Female Rats [J]. Chinese Journal of Magnetic Resonance, 2025, 42(4): 345-354. |
| [10] | LI Yinghao, WANG Lihui, WANG Sucheng, ZHU Zhongqi, HUANG Changdong, LI Renfeng, CAO Kaiming, HU Haiyang, JIA Yiming, LIANG Songtao, YANG Guang, LU Qing, WANG Hongzhi. Study on Pancreas Automatic Segmentation, Regional Quantification, and Diabetes Assessment [J]. Chinese Journal of Magnetic Resonance, 2025, 42(4): 378-389. |
| [11] | GAO Zhaoyao, ZHANG Zhan, HU Liangliang, XU Guangyu, ZHOU Sheng, HU Yuxin, LIN Zijie, ZHOU Chao. PMRI Image Reconstruction Method Based on Virtual Coils and GRAPPA-enhanced Network [J]. Chinese Journal of Magnetic Resonance, 2025, 42(4): 390-401. |
| [12] | MA Yingxue, ZHAO Yanqiang, YANG Xiaodong, JIANG Bin, TAO Cheng. Opportunities and Challenges of High-field and Ultra-high-field Magnetic Resonance Imaging in China [J]. Chinese Journal of Magnetic Resonance, 2025, 42(3): 334-344. |
| [13] | SHU Wei. Diagnostic Efficacy Comparison of B-scan Ultrasonography and MRI in Fetal Skeletal Abnormalities [J]. Chinese Journal of Magnetic Resonance, 2025, 42(3): 265-274. |
| [14] | SUI Meiju, ZHANG Lei, WANG Ruifang, LUO Yingying, LI Sha, QIU Maosong, XU Qiuyi, CHEN Daiqin, CHEN Shizhen, ZHOU Xin. MRI-traceable Nanoenzyme for Cascade Catalysis-enhanced Immunotherapy [J]. Chinese Journal of Magnetic Resonance, 2025, 42(3): 231-248. |
| [15] | MENG Jingxin, WANG Yuanjun. Research Progress on Tractography of Superficial White Matter Based on Diffusion Magnetic Resonance Imaging [J]. Chinese Journal of Magnetic Resonance, 2025, 42(2): 205-220. |
| Viewed | ||||||
|
Full text |
|
|||||
|
Abstract |
|
|||||